RD 500 E
EN
www.magmaweld.com
14
USER MANUAL | KULLANIM KILAVUZU
Installation
2.3 Mains Plug Connection
2.4 MMA Welding Connections
2.5 TIG Welding Connections
For your safety, never use the mains cable of the machine without a plug.
• Since mains connection sockets may vary from factory to factory, an appropriate
plug must be installed o the builtin mains cable of the machine by qualified ele-
ctricians. Please observe that the earth cable is in yellow/green colour and labe-
led as.
• After installing the electric plug, DO NOT INSERT IT INTO THE SOCKET AT THIS
STAGE.
• According to the polarity of the electrode to be used, insert welding cables into
the appropriate outlet
(4)
and tighten them by turning clock-wise.
• Connect the earth clamp tightly to the workpiece as close as possible to the welding
area.
• TIG torch with a valve should be used.
• Connect the TIG torch power cable to the negative outlet
(4)
and the earth cable
to the positive outlet
(4)
of the machine.
• Install the Argon gas regulator onto the Argon gas cylinder.
• Connect the gas hose of the torch to the gas regulator.
Figure 2: Electric Plug Connection
Figure 3: MMA Welding Connections
Figure 4: TIG Welding Connections
Figure 5: Connecting Gas Cylinder