3.1 User Interface
OPERATION
4
5
6
7
1
8
2
10
11
9
3
2- TIG Curve
1- Adjustment Button
The adjustment knob allows current setting in all welding methods and parameter changes in all
functions. The setting will be made by turning right and left and the set values will be displayed on
the digital display.
Use the buttons to scroll through the parameters in the TIG curve. The led of the relevant parameter
will light up depending on which parameter is selected.
Start Current
The welding arc will occur at the specified current value. The value is set in terms of %. Start
current occurs below the specified% value of the main current and allows adjustment from
3 A - %100.
Pre Gas
Darkening - deformation may occur in the welding area, if the shielding gas comes later
than the arc start. In order to prevent this deformation, you can adjust pre gas timing before
arc. Furthermore, the life of the tungsten tip will be shortened. Initial gas function allows
adjustment between 0 -20 sec. By this setting, it is ensured that the gas reaches the welding
area before starting welding.
Operation