![Magmaweld MONOTIG 220ip Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/magmaweld/monotig-220ip/monotig-220ip_user-manual_3534078013.webp)
EN
www.magmaweld.com
MONOTIG 220ip - MONOTIG 220ip AC/DC
13
USER MANUAL | KULLANIM KILAVUZU
2.1 Delivery Control
Symbols and their meanings on the device;
2.2 Installation And Operation Recommendations
Make sure that the all materials you have ordered have been received. If any material is missing or damaged, contact your place of purchase immedia-
tely.
The standard box includes the following:
• Main machine and connected mains cable
• Grounding Clamp and Cable
• Electrode clamp and cable
• Warranty Certificate
• Instruction for Use
• Torch
In the case of a damaged delivery, draw up a record, take a picture of the damage. Report to the transport company together with a photocopy of the
delivery note. If the problem persists, contact the customer service.
For a better performance, place the machine at least 30 cm away from the surrounding objects. Pay attention to overheating, dust and moisture near
the machine.
Do not operate the machine under direct sunlight. If the ambient temperature exceeds 40°C, operate the machine at a lower current or a lower ope-
rating cycle.
Avoid welding outdoors in windy and rainy weather circumstances. If welding is necessary in such cases, protect the welding area and the welding
machine with a curtain and canopy. If you weld indoors, use a suitable smoke extraction system. Use breathing apparatus if there is a risk of inhaling
welding fumes and gas in confined spaces.
Observe the operating cycle rates specified on the product label. Exceeding operating cycle rates can damage the machine and this may invalidate the
warranty.
Use the fuse that is compliant with your system.
Secure the ground cable as close as possible to the welding area.
Do not allow the welding current to pass through equipment other than the welding cables.
Secure the gas cylinder to the wall with a chain.
The welding cables and the mains cable must not be wrapped in the machine housing during operation.
Welding process is dangerous. Proper working conditions should be ensured and necessary precautions should be taken. Specialists are
responsible for the machine and have to be equipped with the necessary equipment. Irrelevant persons should be kept away from the
welding area.
This device is not compatible with IEC 61000-3-12. If it is desired to connect to the low voltage mains used in homes, it is essential that the
installer or the person who will operate the machine to make the electrical connection has information on the machine’s connectivity. In
this case the responsibility will be assumed by the person who will perform the installation or by the operator.
The safety symbols and warning notes on the device and in the operating instructions must be observed and the labels must not be
removed.
Grids are intended for ventilation. The openings should not be covered in order to provide good cooling and no foreign objects should be
inserted.
INSTALLATION INFORMATION
Installation Information