EN
27
www.magmaweld.com
USER MANUAL | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 65 PX / ID 65 P
4.2 Troubleshooting
The following tables contain possible errors to be encountered and their solutions.
Machine is not operating
• There is a problem with the
machine’s electrical connection
• Make sure the machine is connected
to electricity
• If the problem continues, contact the
authorized service
• The mains supply fuse is faulty or the
mains cable is damaged
• Mains voltage may not be appropriate
• Arc does not transfer to workpiece
• Torch and / or consumables may be
worn or damaged
• The grounding pliers may not be
attached to the workpiece or machine
• Check mains supply fuses, mains
cable and plug
• If the problem continues, contact the
authorized service
• Make sure that the mains voltage to
the machine is appropriate.
• If the problem continues, contact the
authorized service
• Make sure the workpiece
surface is unpainted and clean
• Make sure the torch is at the proper
distance from the workpiece
• If the problem continues, contact the
authorized service
• Make sure the torch and / or
consumables are not worn or
damaged, replace if necessary.
• If the problem continues, contact the
authorized service
• Make sure that the grounding pliers
are connected to the workpiece and
the machine. Clean the area where
the grounding pliers contact
the workpiece
• Make sure the grounding pliers are
not damaged
• If the problem continues, contact the
authorized service
• Grid connections are incorrect
• Air pressure and flow may not be
suitable
• On / off switch not working properly
• If the problem continues, contact the
authorized service
• Check the air pressure and air
quality. air pressure and make sure,
that the flow rate is appropriate, the
air is dry and clean.
• If the problem continues, contact the
authorized service
• On/off switch not working properly
• Check the on / off switch
• If the problem continues, contact the
authorized service
The machine is working
but it doesn’t cut
Maintenance and Service
Failure
Reason
Solution