EN
36
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 400 MK PULSE EXPERT / ID 400 MKW PULSE EXPERT
MAINTENANCE AND SERVICE
• Maintenance and repairs to the machine must be carried out by a qualified personnel. Our company will
not be responsible for any accidents that may occur by unauthorized interventions.
• Parts that will be used during repair can be obtained from our authorized services. The use of original
spare parts will extend the life of your machine and prevent performance losses.
• Always contact the manufacturer or an authorized service designated by the manufacturer.
• Any unauthorized attempt other than by the manufacturer during the warranty period will cause all
warranty provisions to be void.
• Always comply with the applicable safety regulations during maintenance and repair.
• Before performing any work on the machine for repair, disconnect the machine’s power plug from the
power supply and wait for 10 seconds for the capacitors to discharge.
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems
are encountered in your device. Depending on the work load and contamination of your work
environment, you can repeat the above processes more frequently.
Never operate the machine when covers are open.
4.1 Maintenance
Daily Maintenance
• The wire feed mechanism must be kept clean and the roller surfaces must not be
lubricated. Each time you replace the welding wire, always clean the residues on
the mechanism with dry air.
• The supplies on the optional TIG torch must be cleaned regularly. Should be
replaced if necessary. It should be ensured that these materials are original
products for a long-term use.
Every 3 Months
• Do not remove the warning labels on the device. Replace worn / torn labels with
new ones. The labels can be obtained from the authorized service centers.
• Check the clamps and cables. Pay attention to the connections and strength of the
parts. Replace damaged / defective parts with new ones. Do not extend or fix the
cables.
• Ensure that enough space for ventilation is available.
Every 6 Months
• Clean and tighten fasteners such as bolts and nuts. Check the electrode clamp and
grounding clamp cables. Open the side covers of the machine and clean with low
pressure dry air. Do not apply compressed air to electroniccomponents at close
distance.
• Replace the water in the tank of the water-cooling unit at periodic intervals with a
soft, clean water and ensure protection against freezing with antifreeze.
or