EN
25
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 400 MK PULSE EXPERT / ID 400 MKW PULSE EXPERT
PAGE 4
Trigger mode selection will be made.
Setting Range
• 2 Trigger
• 4 Trigger
• 6 Trigger
• Method
a) TRIGGER
2 TRIGGER MODE:
When the torch trigger is pressed, welding starts and the trigger will be held pressed
until the welding ends. Releasing the trigger will end the welding.
Welding Start;
Welding Termination;
• Press and hold the torch trigger.
• Release the pressed torch trigger.
• Shielding gas flow starts as long as the pre-gas period.
• The wire feed motor will stop.
• At the end of the pre-gas period, the wire feed motor
• The arc extinguishes after the set
runs at a slow speed.
burn-back time.
• Welding current increases when the workpiece is reached.
• The process ends after the final gas period.
4 TRIGGER MODE:
When the torch trigger is pressed and released once, welding starts and there is no
need to hold it pressed until the welding ends. Pressing and releasing the trigger again will end the welding
process.
Welding Start;
Welding Termination;
• Press and hold the torch trigger.
• Release the pressed torch trigger.
• Shielding gas flow starts as long as the pre-gas period.
• The wire feed motor will stop.
• At the end of the pre-gas period, the wire feed motor
• The arc extinguishes after the set
runs at a slow speed.
burn-back time.
• Welding current increases when the workpiece is reached.
• The process ends after the final gas period.
• Release the pressed torch trigger and the welding will continue.
PrG :
Initial Gas Time
I :
Welding Current
PoG :
Final Gas Time
Press the Trigger
Hold the Trigger Pressed
Release Trigger
PrG :
Initial Gas Time
I :
Welding Current
PoG :
Final Gas Time