Operation
Trigger Mode and Electrode Type Selection Button
While in TIG welding modes; It is used to select one of the 2-Position, 4-Position, Tailstock Position
modes.
When 2-position is selected, led
10
lights up.
When 4-position is selected, led
11
lights up.
When the tailstock position is selected, led
12
lights up.
While in MMA mode; It is used to select one of the rutile, basic, cellulosic electrode modes.
When the rutile electrode is selected, led
10
lights up.
When the basic electrode is selected, led
11
lights up.
When cellulosic electrode is selected, led
12
lights up.
TIG Parameters Selection Buttons
It is used to select the TIG parameter to be adjusted. After the related TIG parameter’s led is on, the
parameter is adjusted to the desired value with the parameter setting button.
You can set the following TIG parameters:
15
Pre-Gas Time
16
Starting Current
17
Start Ramp Time
18
Upstream
19
Understream
20
End Ramp Time
21
End Current
22
Post Gas Time
23
Spot Welding Time
9
13 - 14