background image

17

www.magmaweld.com

USER MANUAL | KULLANIM KILAVUZU

ID 250T DC / ID 300T DC

EN

• Adjustable Pedal Connection; It should be secured to the pedal socket with the ends 

3-4-5-6

.

(3) 

Soldering direction has been taken as the reference.

2.5.4 Grounding Clamps Connections

2.5.5 Installation of Torch Consumables

•  Insert the grounding clamps cable plug

 (a)

 into the positive 

  terminal socket and tighten it by turning right.

• To improve the welding quality, firmly connect the grounding 

 pliers 

(b) 

to the workpiece as close as possible to the welding 

 area.

• The ceramic gas nozzle

 (5)

 and the tungsten electrode

 (1)

 must be selected according to the operating current  

  and the shape of the workpiece. Accordingly, the diameters of the clamp 

(3) 

and the clamp holder

 (4)

 must    

  match with the diameter of the tungsten electrode.

• Remove the clamping cap 

(2)

.

• Remove the existing electrode from the electrode clamp and match the diameter of the new tungsten electrode.

• Secure the collect to the torch.

• Secure the clamping cap firmly head firmly.

Figure 5 : Installation of Torch Consumables

Figure 4 : Grounding Clamps Connections

a

b

1

3

4
5

Installation

Содержание ID 300T DC

Страница 1: ...ID 250T DC ID 300T DC 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...

Страница 2: ...kine Sanayi ve Ticaret A Magma Mekatronik may modify the information and the images without any prior notice T m haklar sakl d r Magma Mekatronik Makine Sanayi ve Ticaret A nin yaz l izni olmaks z n b...

Страница 3: ...TR EN DC WELDING INVERTER DC KAYNAK NVERT R 3 ID 250T DC ID 300T DC...

Страница 4: ...and Operation Recommendations Mains Plug Connection Connection to Mains Connections for TIG Welding Torch Connections Gas Connections Trigger and Pedal System Socket Connections Grounding Clamps Conn...

Страница 5: ...injuries may occur Make certain that the installation procedures comply with national electrical standards and other relevant regulations and ensure that the machine is installed by authorized persons...

Страница 6: ...the above precautions If the gas tanks are grouped in a separate zone ensure that they are well ventilated keep the main valves closed when gas cylinders are not in use pay attention to possible gas...

Страница 7: ...ions you will perform in such places Do not weld in tanks and pipes which might have previously contained substances that may cause explosions fires or other reactions Welding cutting equipment heats...

Страница 8: ...free areas To prevent gas cylinders from tipping over on machines with a gas platform suitable for the tanks fix the tanks on to the platform in stationary usage applications fix them to the wall with...

Страница 9: ...pliance must be carried out All covers on the body of the machine must be closed and or locked when the device is in use Any changes other than the standard settings without the written approval of th...

Страница 10: ...ning materials tape cable ties etc The operator s body and head should be kept as far away from the welding cutting machine and cables as possible Welding cutting and electric cables should not be wra...

Страница 11: ...of thin metal sheets except aluminum for MMA welding of all kinds of stick electrodes up to 5 mm Enhanced professional TIG controls such as HF start Touch Lift Pre Gas Up Slope Pulse Down Slope Post G...

Страница 12: ...s of the 10 minutes period zone 1 However the following 4 minutes should be kept idle for the machine cool down zone 2 Duty Cycle Temperature C 6 min 6 min 6 min 4 min 4 min 4 min Time min Duty Cycle...

Страница 13: ...oled TIG Torch Gas Regulator Argon Water Cooling Unit CST 60i TIG Accessory Set Air Cooled Torch Regulator Foot Pedal On Off Water Cooled TIG Accessory Set Torch Regulator Foot Pedal Current Adjustabl...

Страница 14: ...hine Observe the duty cycle rates specified on the product label Exceeding duty cycle rates can damage the machine and this may invalidate the warranty Use the fuse that is compliant with your system...

Страница 15: ...ety never use the mains cable of the machine without a plug When plugging the power plug into the outlet make sure that the on off switch is set to 0 2 5 Connections for TIG Welding 2 5 1 Torch Connec...

Страница 16: ...inlet at the rear of the machine and turn on the gas cylinder valve Adjust the flow rate with the flow regulating valve e Make sure the connections are free of leakages 2 5 2 Gas Connections a c b d e...

Страница 17: ...he grounding pliers b to the workpiece as close as possible to the welding area The ceramic gas nozzle 5 and the tungsten electrode 1 must be selected according to the operating current and the shape...

Страница 18: ...e electrode manufacturer To improve the welding quality firmly connect the grounding pliers b to the workpiece as close as possible to the welding area 2 6 Connections for MMA Welding Check for the co...

Страница 19: ...no further action is required for recording In addition while still in TIG modes it allows to switch to the cooling time setting when pressed for 3 seconds Digital Program Display Shows the program n...

Страница 20: ...one of the rutile basic cellulosic electrode modes When the rutile electrode is selected led 10 lights up When the basic electrode is selected led 11 lights up When cellulosic electrode is selected le...

Отзывы: