The following effects will occur if the pressure adjustment screw is overtightened,
left loose or if the wrong wire feed roller is used.
Make the gas adjustment and gas test by lifting the wire feed roller pressure lever!
A:
Suitable wire pressure and conduit dimensions.
B:
The wire is distorted since the pressure lever is too tight.
C:
The roller surface is deteriorated due to excessive pressure on the pressure lever.
D:
The conduit length of the roller is small for the wire used. Wire form is distorted.
E:
The conduit length of the roller is big for the wire used. The wire cannot be transmitted to the welding area.
Figure 9 : Pressure Setting and Roller Selection Mistakes
3.9 Adjustment of Gas Flow
• Adjust the gas flow with the flow control valve.
• Practical gas flow rate (CO₂, Ar, mixture) is 10 times of
wire diameter.
For example, if the wire diameter is 0.9 mm, the gas
flow rate can be adjusted as 10 x 0.9 = 9 l / min.
• You can use the table on the side for more precise flow
adjustment.
• After adjusting the gas flow, lift the thrust bearing arm
and close the wire feed unit door.
Operation
8 lt/min.
Mild Steel
and
Metal Cored
Diameter (mm)
0.8
0.9
1.0
1.2
Flux Cored
Stainless
Steel
Aluminium
7 lt/min. 8 lt/min.
8 lt/min.
9 lt/min.
8 lt/min. 9 lt/min.
9 lt/min.
10 lt/min. 9 lt/min. 10 lt/min. 10 lt/min.
12 lt/min. 11 lt/min. 12 lt/min. 12 lt/min.
Содержание COMPACT SMART Series
Страница 1: ...90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL COMPACT SMART SERIES...
Страница 111: ...RU 111 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU COMPACT SMART SERIES KOMPAKT SMART SER S 4 2...
Страница 117: ...RU 117 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU COMPACT SMART SERIES KOMPAKT SMART SER S 5 3...
Страница 153: ......
Страница 154: ......