background image

Содержание MAGMA FOG 1500IP-II

Страница 1: ...User Manual MAGMA FOG 1500IP II...

Страница 2: ...y persons and direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe insufficient and negligen...

Страница 3: ...ines 8 Overview 10 Installation Instructions 11 Accessory Installation Instructions 13 Remote Device Management RDM 14 Remote Control 15 Setup 16 Control Panel 17 System Menu 18 Message Icons 21 DMX T...

Страница 4: ...ing carton in the trash Please recycle whenever possible BOX CONTENTS Twist Lock Power Cable x1 CUSTOMER SUPPORT Contact MAGMATIC customer service for any product related service and support needs Als...

Страница 5: ...instructions guidelines and or user manual D This is not a service contract and this warranty does not include any maintenance cleaning or periodic check up During the periods as specified above Magma...

Страница 6: ...freight pre paid and insured to MAGMATIC in Los Angeles CA or a MAGMATIC Authorized Service Center The RMA number must be clearly written on the outside of the return box and a brief description of t...

Страница 7: ...d for any signs of contaminants Inspect optics to determine if the lens is obstructed then clean optics and chassis accordingly Based on initial finding schedule maintenance accordingly keeping in min...

Страница 8: ...nty and increase the risk of damage and or personal injury PROTECTION CLASS 1 FIXTURE MUST BE PROPERLY GROUNDED THERE ARE NO USER SERVICEABLE PARTS INSIDE THIS UNIT DO NOT ATTEMPT ANY REPAIRS YOURSELF...

Страница 9: ...pt to operate this device if the power cord has been frayed crimped and or damaged Replace any damaged power cords with new cords of the same power rating Do not remove or break off the ground prong f...

Страница 10: ...Hz 5P DMX OUT BOTTOM SIDE REMOTE IN 5P DMX IN NFB 20A Nozzle Fluid Reservoir Cap MagFly Input Cover Mounting Bracket Safety Cable Loop Bracket Adjustment Knob Control Panel Hatch No Fuse Breaker DMX I...

Страница 11: ...professional equipment installer MUST be consulted to determine if the metal truss structure or surface is properly certified to safely hold the combined weight of the device s clamps cables and acces...

Страница 12: ...nting clamps are required to securely install this device in a suspended environment MOUNTING CLAMP ATTACHMENT POINT SAFETY CABLE LOOP ALWAYS ATTACH A SAFETY CABLE WHEN INSTALLING THIS UNIT IN A SUSPE...

Страница 13: ...er Fororderinginformation seetheAccessoriessectionofthismanual 1 Locate the MagFly input cover and remove all 8 screws with a phillips screw driver 2 Insert up to 2 MagFly receiving cards into the car...

Страница 14: ...d The controller can then use its SET command to modify settings that would typically have to be changed or viewed directly via the unit s display screen including the DMX Address DMX Channel Mode and...

Страница 15: ...when the button is released The LED illuminates when unit is outputting and settings are set on the device s display screen Continuous Button Unit outputs when button is pressed the first time and con...

Страница 16: ...Neverruntheunitonanythingotherthan approved MAGMATIC branded fluid as doing so can result in severe damage to your device 3 Screw the tank cap back onto the fluid tank Be careful not to pinch twist o...

Страница 17: ...and use the UP and DOWN buttons to make adjustments Press the ENTER button to confirm your adjustments You may exit the main menu at any time without making any adjustments by pressing the BACK EXIT...

Страница 18: ...transmit on LCD Set Screen OFF Never 10s 40s 1min 2min 5min 10min 20min Display blackout time MagFly Set MagFly Channel 0 14 Magfly channel setting MagFly On Off Magfly activation No Fluid On Off Acti...

Страница 19: ...djustable Preset 2 30s duration fog 80 10s interval Preset setting 2 not adjustable Preset 3 60s duration fog 60 30s interval Preset setting 3 not adjustable Preset 4 150s duration fog 40 120s interva...

Страница 20: ...urrent Wifi IP status MagFly Ch 00 14 Current MagFly channel setting DMX Addr 1 512 Current DMX address DMX Mode 1 2 4 Current DMX channel mode Timer Output 0 100 Current timer output Timer Int 0s 250...

Страница 21: ...Icon appears when MagApp module is connected 4 bar symbol on the right indicates signal strength with 0 bars being weakest and 4 bars being strongest Icon appears when MagRF module is connected Note t...

Страница 22: ...ALUES FUNCTION 1 CH 2 CH 4 CH 1 1 Fog 000 005 Off 006 255 On 1 2 2 000 255 Volume 1 to 100 output is continuous at 20 or less 3 Duration 000 005 0s 006 255 1s 250s 4 Interval 000 005 0s 006 255 10s 25...

Страница 23: ...ESSURE TESTING PARAMETERS Low Pressure Limit High Pressure Limit Steady Hold Time 3 04PSI 21kPa 4 49PSI 31kPa 30 seconds CAUTION THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS STRONGLY RECOMMENDED...

Страница 24: ...E IP TESTER CONTACT SERVICE SERVICE FOR MORE DETAILS 9 5 0 5 kgf cm Screw 8pcs copper pillar 6pcs 6 0 5 kgf cm Screw 8pcs Copper cover over 300 20 0 kgf cm 2pcs 5 5 0 5 kgf cm Waterproof connector 5 5...

Страница 25: ...rate correctly the unit will require service Please contact Magmatic Effects for assistance CLEANIN G MA I NTENANC E Store this device in a cool area and cover the device in order to prevent dust buil...

Страница 26: ...26 DIMENSIO NAL DRAWINGS 648mm 25 5in 337mm 13 3in 298mm 11 7in 411mm 16 2in 313mm 12 3in 267mm 10 5in...

Страница 27: ...nsceiver Optional MAGRF Wireless and MAGREMOTE Wired Remotes CONNECTIONS Locking 5pin XLR Connector DMX In Out IP67 Locking Power Connector In With Wired Digital Communication Network SIZE WEIGHT Leng...

Страница 28: ......

Отзывы: