1-800-MAGLINE (624-5463)
Page 18 www.magliner.com
CooLift
®
Troubleshooting - CPA Models
Problem
Possible Causes
Remedy
The unit does not
turn on.
Main power switch
Make sure the main switch is turned on.
Battery power
Make sure the batteries are charged.
Circuit breaker
Check the circuit breaker; if it has been tripped,
reset it.
Electrical connections
Check electrical connections for tightness,
including battery terminals within the
enclosure.
The CooLift is not
charging up.
Charger
Make sure that the charger is working correctly.
Make sure the charger is in the correct mode.
All CooLift CPA models need the NOCO charger
set to 12V Standard.
Make sure there is no damage to the plug or
cord; replace any damaged items.
Make sure the power plug is plugged into the
charger socket.
Make sure the charger output cord is plugged
into the batter pack charger port.
Abbreviated information below; See pages 15-
17 of the Owners Manualfor complete charger
information.
Electrical connections
Check electrical connections for tightness,
including battery terminals within the
enclosure.
AC Charging Unit LED Indicators
The flashing red lights indicate the charging phase while the batteries are charging.
•
1 bar = 0-25% charged. The light will turn solid when 25% charge is reached, and the next light will begin to flash.
•
2 bars = 25-50% charged. The light will turn solid when 50% charge is reached, and the next light will begin to flash.
•
3 bars = 50-75% charged. The light will turn solid when 75% charge is reached and the next light will begin to flash.
• Flashing green light + 3 red light = 75-95%, this DOES NOT mean fully charged.
•
Maintenance mode (flashing green + 0 red lights) = 95-100%, means battery is optimizing the charge going into the
battery, which ensures the battery is not overcharged. This prolongs battery life.
• Solid Green light = 100% fully charged
Normal Charging Lights
Correct Charger Mode