22
P66
Enables RS485
0
n°
P74*
IN11 Input Configuration
0
n°
P83*
IN12 Input Configuration
0
n°
P84*
IN13 Input Configuration
0
n°
P92
Percentage variation of the Combustion Fan speed during
the Periodic Cleaning
20%
n°
P93
Percentage variation of Auger speed/On time during the
Periodic Cleaning
-30%
n°
P111
Maximum amount of pellet the stove may contain
21
Kg
P112
Amount of pellet used in 10 minutes with the auger at
half of its maximum speed. To calculate the value, use the
function ‘Loading Test’.
830
gr
P118
Auger Off time in Unlock function
2.0
sec
Menù Delta
Parametro Descrizione Funzione
Hevo
14
Hevo
18
Hevo
21
U.M
D01
Exhaust flue gas temperature increasing Delta in
Stabilization
50
°C
D08
Water temperature Delta for automatic combustion
regulation
5
°C
D23
Delta to add to the Boiler Thermostat to pass from
Modulation to Standby at the end of T43 if A13=1, 2.
5
°C
D41
Ignition Delta
20
°C
Menu to Restore the Default Parameters
Sottomenù
Descrizione Contatore
Totally hours
Totally time operation
Hours of operation
Operation time: time while also one component works.
Run mode hours
Operation time
Ignition N°
Number of successful ignition attempts
Ignition failed N°
Number of failed ignition attempts
N° Errori
Total Error
Reset Contatori
Reset all counters
Menù Test Ouputs
Menu that allows the test of the single outputs of the board (therefore of the loads connected to
it) with the system in the Off state. If you leave them on, the outputs will automatically turn off
after 30 seconds.
Sottomenù
Descrizione
Smoke exhaust
Test Smoke exhaust
Cleaning brazier Motor
Test Cleaning brazier Motor
Auger
Test Auger
Heater – A1
Test Quarz Heater
V3
Test Motor external Tank
Aux1
Test Pompa 2 o valvola motorizzata se prevista
A2
Pump 2 or 3 way valve
A3
Shutter linear
A4
Pump 1
A5
Pellet Aspiration motor
Содержание HEVO 14