PUFFER MANAGEMENT WITH TWO PROBES, HIGH PUFFER PROBE AND LOW PUFFER PROBE

 

 

 

 

 

It is recommended to tap the supply water of the heating system from the Puffer at a height higher than or 
equal to the Puffer S2 probe.  

The Puffer High (S2) probe was previously connected and configured in IN 3 (clamps 35-36). At this point it 
will  be  necessary  to  connect the  Low  Puffer  Probe  (S3)  in  Input  8(IN8,  clamps  48  –49)  and  through  the 
System –Settings menu, set parameter P71 to 23.  

Now through the User’s Menu, Heating managing it will be possible to set the desired temperature of both 
probes.  

Probe operation logic: The boiler passes into the Stan-by state when both probes (S2 and S3) are satisfied 
and therefore both Puffer Probe thermostats (Low and high) have reached the temperature set in the User’s 
Menu – Heating Management.  

 

The boiler will exit the Stand-by state and then restart heating if Puffer Probe High (S2) temperature is < of 
the Puffer High Probe Thermostat –Ih58 -1. 

Example:  

Puffer High Probe Thermostat (S2) = 50° (setting adjustable via user menu –Heating Management) 

Ih58 = Puffer Thermostat Hysteresis S2 = 8° (Default setting –adjustable via System Menu –Thermostats  

Puffer Low Probe Thermostat (S3) = 70° (adjustable setting via User Menu –Heating Management) 

Puffer High Probe 

Thermostat (S2 = 50°) 

Puffer Low Probe 

Thermostat (S3 = 70°) 

Stato Funzionamento 

Caldaia 

S2 < 50° 

S3 < 70° 

Run Mode (ON) 

S2 > 50° 

S3 < 70° 

Run Mode (ON) 

S2 > 50° 

S3 > 70° 

Stand-By 

 

 

 

 

 

 

 

 

 

 

 

Содержание HEVO 14

Страница 1: ...TECHNICAL MANUAL HEVO 14 18 21 ENGLISH...

Страница 2: ...l bodies During installation the staff must refer to the following Laws and Regulations D M No 37 22 01 2008 Reordering of the provisions on the installation activities of the plants inside the buildi...

Страница 3: ...1 5 2 2 Chimney and fumes Pipe 6 2 3 Hydraulic installation 7 Electronic Unit 13 3 1 Schema elettrico 14 3 2 Environment thermostat 15 Loading System 16 4 1 Manual Loading 16 4 2 Automatic Load 17 Tec...

Страница 4: ...erage smokes temperature C 154 83 158 83 160 83 Average draft Pa 10 10 10 Inner tank capacity Kg 20 20 20 Autonomy h 7 25 5 25 5 25 Heatable volume nominal m 350 410 490 Air taking 50 50 50 Smokes exi...

Страница 5: ...table protection as long as it does not reduce the minimum section to 100 cm2 The minimum ambient volume must not be less than 20 m The air inflow can also be obtained from rooms adjacent to the insta...

Страница 6: ...commended to extend the vertical stretch by one meter and for each horizontal section it is recommended to extend the vertical section by 2 meters In the case of vertical developments greater than 7 m...

Страница 7: ...e 2 5bar Expansion vase 6 lt Not in the picture Heating Production of Hot Water Wilo circulator high performance 2 5 6 Air Escape automatic Safety valve 2 5bar Expansion vase 6 lt Not in the picture C...

Страница 8: ...er easier for any extraordinary maintenance Effect the connection by using intercept valves sphere gate valves in order to simplify any maintenance operation Connect the output of the safety valve to...

Страница 9: ...ereafter the function logics will be explained Configuration 0 P26 0 Default from production Apparel coupled with a gas boiler in the heating only version In order to connect the boiler to another gas...

Страница 10: ...h21 in order to guarantee a constant production of hot water In this case if the installed boiler produces also hot water the flow the exchanger and the motorized valve are already originally present...

Страница 11: ...mostat the boilers goes to Stand by position When the temperatures goes under 63 C Puffer temperature 79 8 the boiler interrupts the stand by position and starts Configuration 4 P26 4 Puffer technical...

Страница 12: ...boiler passes into the Stan by state when both probes S2 and S3 are satisfied and therefore both Puffer Probe thermostats Low and high have reached the temperature set in the User s Menu Heating Manag...

Страница 13: ...vent from the radiator taps Check that the pressure of the system is stable checking for any water leaks In case the pressure is stable and there is no water leakage the product is hydraulically ready...

Страница 14: ...fer DHW Boiler S2 Display MultiTouch G W Probe K Aspiration Inlet MicroSwitch B M R B R M Encoder Exhaust Pellet Sensor Level Probe Puffer low S3 M M W Blue Pressure switch Safety Thermostat B B Clean...

Страница 15: ...d The System goes in the State of Standby Environment if A01 3 Probe Environment Thermostat not reached The system reactivates Pump 1 Probe Environment Thermostat reached If the temperature of the wat...

Страница 16: ...pplied with the boiler will be inserted later 4 1 Manual Loading The manual loading is carried out directly by the intake of the pellets out of the bag To ensure a closed pellet load without any clogg...

Страница 17: ...of the plug in which the supplied hose must be connected which in turn must be connected to the in outlet indicated above present in the lower part of the boiler Joining in which the supplied hose sh...

Страница 18: ...haust Speed in Power 3 1600 1750 1900 rpm V06 Exhaust Speed in Power 4 1750 2100 2300 rpm V07 Exhaust Speed in Power 5 1950 2500 2700 rpm V09 Extinguishing Speed 2600 2600 2600 rpm V10 Exhaust Speed i...

Страница 19: ...0 C Th78 Buffer tank Probe Safety Thermostat 80 C Th80 DHW probe Safety Thermostat 75 C Th81 Differenziale Sonda Puffer Sonda ACS 8 C Th83 DHW Thermostat Maximum Range 65 C Th85 Low Buffer tank Thermo...

Страница 20: ...at D23 and A13 1 2 30 sec T46 Working time of the Valve if T42 expired 10 sec T57 Minimum duration time of Standby phase 30 sec T58 Brazier Final Cleaning in Standby 120 sec T66 System operating hours...

Страница 21: ...n 1 Management Auger Brake 1 enabled A29 0 System Management in Standby for Room Thermostat 0 it does not exit for DHW demand 1 n 1 System Management in Standby for Room Thermostat 1 g it exits for DH...

Страница 22: ...to pass from Modulation to Standby at the end of T43 if A13 1 2 5 C D41 Ignition Delta 20 C Menu to Restore the Default Parameters Sottomen Descrizione Contatore Totally hours Totally time operation H...

Страница 23: ...n the boiler must be about 10 k at the temperature of 25 degrees C and decrease as the temperature detected to increase as the temperature drops To measure the resistance of the probe it is necessary...

Страница 24: ...chimney in accordance with the UNI 10683 2012 standard Check the cleaning status of the chimney if necessary clean the same carefully by eliminating all combustion residues inside especially on change...

Страница 25: ...he water not 0 degrees Celsius for example The resistance of the NTC probe that detects the temperature of the water in the boiler must be about 10 k at the temperature of 25 degrees C and decrease as...

Страница 26: ...e the electronic control unit that does not correctly interpret the temperature detected by the probe itself Warning Er07 PROBLEM The boiler s electronic control unit does not detect the fume extracto...

Страница 27: ...the Voltage is proportional to the water pressure 0 8bar plus 0 8 volts 1 bar plus 1 Volt etc etc then replace the electronic control unit that does not correctly detect the pressure transducer signal...

Страница 28: ...ssure transducer not working Measure the power voltage of the pressure transducer on contacts 37 and 39 of the electronic control unit If the Voltage is different from 5 Volts VDC replace the electron...

Страница 29: ...menu measure the power voltage of the measurable cochlea engine on its contacts The voltage measured without disconnecting the engine must be 230 volts VAC If the voltage is not present do the same di...

Страница 30: ...en 1 and 50 minutes the boiler when the power is restored is in the Power Recovery state performing the shutdown phase and then automatically turns it back on Other signals Sond Display status of Temp...

Страница 31: ...31 REVISIONE 00 Magikal Srl Via Alpone 22 37032 Monteforte D Alpone Tel 045 6106342 Fax 045 6107773 magikal magikal it www magikal it...

Отзывы: