background image

Users, 

Installation & Servicing

 

Instructions 

 

MUST BE LEFT WITH THE USER 

 

Solitaire

 

 

Models: 

 

MS16T & MS18T 

16” & 18” Fires  

 

ST16 & ST18 

16” & 18” Fires c/w Thermobox 

 (LPG models prefixed with the letter L) 

 

Fuel Effect Options: 

Coal Effect – NG and LPG 

Pebble Effect - NG Only 

 

Control Options: 

Manual Control 

Remote Control (Response-S) 

Optimum Control 

Trim Switch Control 

 

 

For use on Natural Gas (G20) at a supply pressure of 20mbar  

or Propane (G31) at a supply pressure of 37mbar in GB and IE 

(Dependent upon model)

 

Содержание MS16T

Страница 1: ...mobox LPG models prefixed with the letter L Fuel Effect Options Coal Effect NG and LPG Pebble Effect NG Only Control Options Manual Control Remote Control Response S Optimum Control Trim Switch Contro...

Страница 2: ...ne year of purchase Magiglo will arrange to repair or replace the item free of charge Any claims under this warranty must be made through the retailer from whom the product was purchased As the purcha...

Страница 3: ...lot 19 2 9 3 Cleaning the Fire Back Thermobox Only 19 2 9 4 Black Painted Metal Surfaces 19 2 9 5 Brass or Chrome Surfaces 20 2 9 6 Stainless Steel 20 2 9 7 Care of Ceramic Backs 20 3 Installation Ins...

Страница 4: ...tch Control Model 35 3 9 4 Commissioning 35 3 9 5 Checking for Spillage 36 3 9 6 Instructing the User 36 4 Servicing Instructions 37 4 1 General Requirements 37 4 2 Servicing Instructions 37 4 3 Repla...

Страница 5: ...andards BS 5871 Pt 3 Installation of Decorative Fuel Effect Gas Fires BS 6891 Pipe work Installation BS 5440 Pts 1 2 Flues and Ventilation BS EN 1856 Chimneys Requirements for metal chimneys System ch...

Страница 6: ...may be applicable Please refer to the full Flue Requirements SECTION 3 2 within the Installation Instruction section Gas Supply 1 This range of decorative gas fires are suitable for use with either Na...

Страница 7: ...um of 5 square inches of free air space below the base of the fire Minimum opening free air in fire fret Minimum opening free air in ash pan cover Figure 1 Fire Front Specification Height to Centre A...

Страница 8: ...Page 4 This page is left intentionally blank...

Страница 9: ...fire as shown and follow the appropriate operating instructions in the appropriate section Control Valve Operation Control Type Manual Manual BM Control See Section 2 1 1 on Page 6 Manual Manual Mert...

Страница 10: ...anually by applying a lighted match or taper to the pilot jet and following the above procedure NOTE No attempt should be made to relight the fire for at least 3 minutes after the pilot flame has been...

Страница 11: ...Turn the GAS RATE ADJUSTING KNOB fully anticlockwise until you reach the stop position i e the maximum gas rate See Figure 9 5 The main burner will have cross lit from the pilot 6 Now the gas rate ca...

Страница 12: ...his process the main burner will ignite from the pilot 7 By pressing the two buttons together to increase the gas rate and the lower button only to decrease the gas rate the valve can be manipulated t...

Страница 13: ...main flame position 6 Press and hold the large flame button in Figure 12 Figure 13 until clicking is heard fully open 7 The main burner will have cross lit from the pilot 8 Now the gas rate can be adj...

Страница 14: ...Receiver Unit 1 Remove the receiver unit from under the fire burner or from wherever positioned if mounted remotely and remove the battery compartment cover see diagram 2 Replace the old batteries wit...

Страница 15: ...up 5 Secure with screws REAR OF WALL PLATE CABLE TO VALVE BATTERY PACK 4 x 1 5 V AA BATTERIES LOW OFF SWITCH HIGH SWITCH brown brown brown blue blue blue white black Figure 18 2 4 Battery Replacement...

Страница 16: ...cing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire to ensure that the release of fibres from thes...

Страница 17: ...t in a poor flame picture The best results come from a loose fuel build 5 Do not place any coals immediately over the pilot assembly 6 After the appliance has been allowed to warm up small adjustments...

Страница 18: ...on tubes Pebbles H E and place them on the tray as shown in the relevant figure ensuring that the burner port and path to the pilot assembly remain clear as shown Note that the aeration tubes should b...

Страница 19: ...C C A D Solitaire 16 3rd and Front Layer E F F Solitaire 16 Top Layer Figure 22 Solitaire 16 Fire E E E E E E E H H H H Solitaire 18 Layer 1 A B A B B K K K K K Solitaire 18 Layer 2 B C B D C D A B A...

Страница 20: ...lise the trim as necessary Magnets Figure 24 2 7 Fitting an ioss Fascia if supplied 1 The Fascia is coated with a protective film This must be removed by peeling off before fitting the fascia 2 The fa...

Страница 21: ...ly appliances generating heat will create warm air convection currents that will transfer heat to any wall surface against which they are located Some soft furnishings including blown vinyl wallpapers...

Страница 22: ...eplacing Components containing Refractory Ceramic Fibres RCF we recommend that the replaced items are not broken up but are sealed within heavy duty polythene bags and clearly labelled as RCF waste RC...

Страница 23: ...ezers if available or a piece of fine soft wire pick out the lint from the lint guard 2 With the aid of a small nozzle attachment on your vacuum cleaner apply suction at the lint guard on the pilot Ve...

Страница 24: ...ely removed the surface can then be re polished using 3M Scotchbrite pads Fine Grade Periodically it may be necessary to coat the entire surface in order to achieve a uniform finish This can be achiev...

Страница 25: ...as Installations 2 A faulty flue or chimney may result in smoke and fumes entering the room 3 The flue should be sound free from obstructions and if it has previously been used with a solid fuel or oi...

Страница 26: ...e minimum dimensions as shown in Figure 28 There must be a minimum of 50mm clearance from any combustible material alternatively the box may be insulated with 25mm Rockwool or equivalent The top of th...

Страница 27: ...litaire 6 9kW Models Only REGISTER PLATE 125mm 5 FLEXIBLE LINER SECTION THROUGH MASONRY CHIMNEY 90mm min Figure 29 3 2 5 Installation Example Using Existing Milner Clay Fireback 16 Solitaire 6 9kW Mod...

Страница 28: ...GV34 BM Mertik GV34 Pilot SIT OxyPilot 9039 SIT OxyPilot 9039 SIT OxyPilot 9039 LPG Gas Models Solitaire 16 6 9kW Solitaire 16 7 8kW Solitaire 18 9 0kW Nominal maximum heat input 6 9 kW gross 7 8 kW g...

Страница 29: ...on Approved Document J paragraph 3 40 currently states Appliance should be placed on hearths unless a they are installed so that every part of any flame or incandescent material will be at least 225mm...

Страница 30: ...of 200mm A minimum of 200mm HW A minimum of 700mm A minimum of 750mm HD Must project a minimum of 300mm in front of any naked flame or incandescent material Must project a minimum of 300mm in front o...

Страница 31: ...ed decorative bar etc All Solitaire Models W Must project a minimum of 150mm either side of any naked flame or incandescent material D Must project a minimum of 300mm in front of any naked flame or in...

Страница 32: ...le of physical barrier dimensions as stated in Table 2 Protected Area D W Figure 40 Example of physical barrier dimensions as stated in Table 2 Protected Area D W 50mm Min Figure 41 Example of physica...

Страница 33: ...pose provided ventilation must be checked periodically to ensure it is free from obstructions When fitting the fire in Northern Ireland NI purpose provided ventilation must be provided in accordance w...

Страница 34: ...and must not be used with solid fuel 3 8 2 Initial Installation All Models The following notes are applicable to all three Thermoboxes prior to installation Upon completing this section proceed to th...

Страница 35: ...nect the fire to the gas supply via the isolating valve supplied 7 Adjust the top two clamping screws to secure the top of the box into the fireplace opening Note The black fixing screws used in the t...

Страница 36: ...e of the Thermobox or fireplace inset Each model of Magiglo s Thermobox is supplied with full installation instructions and these should be read thoroughly before commencing installation Note Any fire...

Страница 37: ...ansit tape 8 For Manual Control models Proceed to Section 3 9 4 For other control options proceed to instructions from those in Sections 3 9 1 to 3 9 3 as applicable If Installing a Remote Control tap...

Страница 38: ...ring correct polarity The cable connectors must be matched to the appropriately sized spade connector Also ensure that the cable is neatly tucked away and not touching the underside of the tray 5 Fit...

Страница 39: ...lot in accordance with the User Instructions 4 Set the controls to give full gas rate at the main burner 5 With the correct supply pressure at the inlet point ensure that the pressure at the pressure...

Страница 40: ...onnect the fire and seek expert advice The imitation fuels must be laid in accordance with the instructions prior to commencing the spillage test If there are any extractor fans in the nearby rooms th...

Страница 41: ...hat the gas and electrical supply where applicable have been isolated After any servicing or replacement of any parts the appliance should be re commissioned 4 2 Servicing Instructions As part of the...

Страница 42: ...embly 6 Refit in reverse order ensuring that the lint guard is fitted 4 3 2 Injector Replacement 1 Undo the two compression nuts on the gas feed pipe to the injector elbow s and remove the pipe 2 Loos...

Страница 43: ...the cover and pull out the cover 5 Turn the gas rate adjusting knob fully anticlockwise and gently manipulate the motor free from the valve see note 6 Replace with new motor ensuring that the motor i...

Страница 44: ...lve end Remake thermocouple ensuring the connection is firm Pilot lights but goes out when control is released b Faulty Thermocouple Replace complete pilot assembly a Gas supply partially blocked Loca...

Страница 45: ...n buttons are pressed c Flat batteries in battery holder Trim Switch and Optimum Control Replace all 4 AA batteries Remote Control will turn fire off but will not turn on Incorrect hand set operation...

Страница 46: ...Page 42 This page is left intentionally blank...

Страница 47: ...Page 43 This page is left intentionally blank...

Страница 48: ...UK patents 2193802 2240620 and 2256920 Other Patents Pending Magiglo is a registered trademark of Magiglo Ltd Magiglo Ltd Lysander Close Broadstairs Kent CT10 2YJ Tel 01843 602863 Fax 01843 860108 www...