3.9. Installation Procedure (Fire)
If applicable, carefully unpack the contents of the carton and check them against the checklist
given in
Make sure that the fireplace opening is suitable for the installation of the fire and prepare the
fireplace to suit the dimensional requirements given in sections
and
(i.e. fitting
the fire surround, the hearth, etc.).
1. For all models, place the burner centrally
within the fireplace opening and position
it as far back as possible.
2. Mark the location holes on the legs
through onto the hearth.
3. Remove the burner tray, drill, plug and
secure the burner tray back to the
hearth.
4. No part of the burner tray should be
allowed to project beyond the vertical
plane of the fireplace opening.
5. Connect the gas supply to the fire tray
via the isolating valve supplied. Route
the cable for the Optimum Control if
applicable
6. For LPG models, the gas bottle must be
fitted with a non-adjustable, low-pressure
regulator 37mbar (GB).
7. Remove the transit tape.
8. For Manual Control models. Proceed to
Section 3.9.4
. For other control options,
proceed to instructions from those in
Sections 3.9.1
as applicable.
If Installing a Remote Control
taper model, fit the heat shield
to the hearth in an appropriate
position under the burner tray.
3.9.1. Continuation of Installation - Remote Control Model
1. Unpack the box containing the Receiver
and the Hand Set.
2. Fit four AA (1.5V) batteries into the
receiver unit and the PP3 (9V) battery
into the transmitter (hand set).
3. Feed the cable from the receiver unit
heat shield to the spade terminals on the
control valve, keeping the cable clear of
the underside of the tray. The cable
connectors must be matched to the
appropriately sized spade connector.
4. Position the receiver under the heat
shield as shown in
5. Test the operation of the drive motor
using the hand set as per Users
Instructions (
Section 2.1.2 -
Procedure (Manual Mertik Control)
on
page
6. Proceed
to
Section 3.9.4
to commission
the installation.
IGNITION
KNOB
GAS RATE
ADJUSTING
KNOB
GAS VALVE
PRESSURE
TEST POINT
RECEIVER/
BATTERY
HOLDER
HEAT
SHIELD
Figure 43 – Location of Receiver Assembly (note that
gas fire detail may vary)