current edition of I.S.813 which makes clear the conditions that must be met to
demonstrate that sufficient ventilation is available.
2. Models with heat inputs in excess of 6.9kW require a minimum of 100cm
2
ventilation in the
room where the fire is installed when installed in Great Britain (GB) and in IE, reference
should be made to the current edition of I.S.813 which makes clear the conditions that
must be met to demonstrate that sufficient ventilation is available.
3. If provided, any purpose provided ventilation must be checked periodically to ensure it is
free from obstructions.
4. When fitting the fire in Northern Ireland (NI), purpose provided ventilation must be
provided in accordance with the rules in force.
5. In other EC countries equivalent rules in force must be used.
Flue Requirements
The flue serving this appliance shall have no cross sectional dimension less than 175mm
(7”) e.g. 225mm (9”) by 225mm (9”) Masonry chimney or 175mm (7”) diameter clay liner.
However, should the model being installed have a heat input of 6.9kW then the flue
requirements as set out in
SECTION 3.2.2
may be applicable. Please refer to the full Flue
Requirements
SECTION 3.2
within the Installation Instruction section.
Gas Supply
1. This range of decorative gas fires are suitable for use with either Natural Gas (G20) at
20mbar supply pressure, or LPG (G31) at 37mbar supply pressure (please check
appliance data plate for compatibility).
2. A separate means of isolating the gas supply should be provided near to the appliance to
facilitate servicing. For this, an isolation valve has been supplied with the appliance.
Electrical Supply
Not applicable to this range of appliances.
1.1. Important Note About ODS Pilot
This fire is fitted with an ODS pilot which causes the appliance to shut down in the event of a
reduction of oxygen (e.g. caused by poor ventilation) in the room. Should this happen, follow
the lighting instructions to re-light the fire. In the event that the fire should shut down again,
do NOT attempt to re-light it but contact your gas installer for remedial action to be taken.
Under no circumstances should it be adjusted or put out of action by the installer
or the user. In case the pilot needs replacing, only the approved part (available
from your supplier or Magiglo Ltd.) should be fitted. Note: if any part of the pilot
assembly becomes faulty the complete assembly will need replacing.