14.

 

Operating

 

Instructions

 

for

 

remote

 

operation

 

 

NOTE

 

THIS

 

SECTION

 

REPLACES

 

THE

 

SECTION

 

‘TO

 

LIGHT

 

THE

 

HEATER’

 

CONTAINED

 

IN

 

THE

 

USERS

 

INSTRUCTIONS

 

1. 

Batteries

 

 

The

 

handset

 

takes

 

a

 

standard

 

9v

 

battery.

 

This

 

should

 

be

 

changed

 

annually

 

to

 

ensure

 

the

 

fire

 

continues

 

to

 

operate

 

correctly.

 

It

 

can

 

be

 

accessed

 

through

 

a

 

flap

 

on

 

the

 

back

 

of

 

the

 

handset.

   

The

 

fire

 

is

 

fitted

 

with

 

a

 

special

 

7.2volt

 

rechargeable

 

battery

 

available

 

from

 

your

 

retailer

 

or

 

from

 

Magiglo

 

on

 

01572

 

725570.

   

It

 

can

 

be

 

changed

 

by

 

simply

 

sliding

 

it

 

out

 

of

 

its

 

housing

 

under

 

the

 

fire,

 

undoing

 

the

 

connector

 

block

 

and

 

carefully

 

replacing

 

with

 

a

 

new

 

one

 

2. 

We

 

regret

 

that

 

the

 

warranty

 

does

 

not

 

cover

 

items

 

such

 

as

 

batteries.

    

When

 

disposing

 

of

 

batteries,

 

always

 

do

 

so

 

in

 

an

 

environmentally

 

friendly

 

manner.

 

3. 

On

 

first

 

operation,

 

ensure

 

the

 

thermostat

 

is

 

set

 

to

 

the

 

hot

 

position.

 

4. 

Ensure

 

the

 

infra

 

red

 

sensor

 

is

 

visible.

 

The

 

fire

 

relies

 

on

 

line

 

of

 

sight

 

between

 

the

 

sensor

 

and

 

handset

 

to

 

operate.

 

If

 

a

 

different

 

fret

 

is

 

fitted

 

it

 

is

 

possible

 

to

 

swivel

 

and

 

slide

 

the

 

sensor

 

into

 

a

 

clearer

 

position.

 

In

 

the

 

event

 

of

 

the

 

fire

 

not

 

working

 

check

 

both

 

of

 

the

 

above

 

points

 

before

 

calling

 

an

 

engineer.

 

5. 

To

 

ignite

 

the

 

fire,

 

point

 

the

 

handset

 

at

 

the

 

fire,

 

push

 

and

 

hold

 

simultaneously

 

the

 

2

 

left

 

hand

 

buttons

 

marked

 

*

 

and

 

 

for

 

several

 

seconds

 

until

 

the

 

igniting

 

sequence

 

begins.

 

The

 

fire

 

will

 

automatically

 

light

 

the

 

pilot

 

light,

 

monitor

 

its

 

safety

 

for

 

about

 

20

 

seconds

 

and

 

then

 

it

 

will

 

light

 

the

 

burner

 

on

 

high

 

flame.

 

6. 

To

 

alternate

 

between

 

high

 

and

 

low

 

flame

 

use

 

the

 

flame

 

buttons

 

on

 

the

 

right

 

hand

 

side

 

of

 

the

 

handset.

 

7. 

To

 

turn

 

the

 

fire

 

OFF

 

press

 

the

 

 

button

 

on

 

the

 

top

 

left

 

hand

 

side

 

of

 

the

 

remote

 

handset.

 

8. 

The

 

fire

 

is

 

fitted

 

with

 

a

 

comfort

 

thermostat

 

behind

 

the

 

ash

 

pan

 

door

 

and

 

it

 

is

 

possible

 

to

 

set

 

this

 

to

 

modulate

 

the

 

fire

 

between

 

off

 

and

 

on.

 

If

 

the

 

pilot

 

is

 

alight

 

but

 

the

 

main

 

burner

 

will

 

not

 

light,

 

check

 

the

 

position

 

of

 

this

 

thermostat

 

before

 

changing

 

batteries

 

etc.

 

9. 

An

 

audible

 

signal

 

is

 

heard

 

when

 

the

 

fire

 

receives

 

a

 

signal

 

from

 

the

 

handset.

 

This

 

will

 

help

 

you

 

to

 

know

 

that

 

the

 

fire

 

has

 

received

 

your

 

instruction

 

and

 

is

 

changing

 

settings.

 

When

 

the

 

battery

 

power

 

is

 

low,

 

a

 

continuous

 

bleep

 

will

 

be

 

heard

 

from

 

the

 

fire

 

and

 

it

 

will

 

allow

 

you

 

to

 

shut

 

down

 

safely

 

but

 

will

 

not

 

reignite.

 

Please

 

then

 

recharge.

 

 

 

 

Содержание EMPATHY 16"

Страница 1: ...iances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 725570 Fax 44 0 1572 724390 e mail info magiglo co uk web www magiglo co uk MAG4240InstUser G20 31 Issue JUNE10 v1 TO OBTAIN YOUR F...

Страница 2: ...n Injector manual valve Elbow 92 300 Elbow 92 90 Injector remote Elbow 92 170 Elbow 92 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and...

Страница 3: ...o cubic metre m divide the room volume in cubic feet by 35 3 3 7 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting rooms basements which are...

Страница 4: ...rectly against a wall 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommend that this spacer is left on as it will keep the surfaces of the fireplace cooler Any combustible mater...

Страница 5: ...small hearth 50mm deep will be required to support the fire front No other hearth is required For all other applications use the hearth sizes in 4 8 4 14 Closure plate tape and foam seals are unsuita...

Страница 6: ...e pushing gas pipes through walls seal the pipe ends to prevent debris entering the pipes 6 4 Drill and fit cable fixing positions in accordance with diagram or alternatively drill and fit screws thro...

Страница 7: ...he burner It is important for clean burning that the correct moulding is fitted in the correct place There must be a clear gap between the two sets of coals pebbles Always replace the glass after layi...

Страница 8: ...he pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot only the pressure must still be within the tolerance of 1mb If it is not...

Страница 9: ...essive exposure to these materials may cause temporary irritation to the eyes skin and respiratory tract consequently it makes sense to take care when handling these parts to ensure that the release o...

Страница 10: ...utlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading The catalyst is u...

Страница 11: ...urpose made battery housing Note If the fire emits a beeping sound this is just the safety system priming itself Because the remote control uses battery power when in the stand by mode The battery wil...

Страница 12: ...r into a clearer position In the event of the fire not working check both of the above points before calling an engineer 5 To ignite the fire point the handset at the fire push and hold simultaneously...

Страница 13: ...the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least...

Страница 14: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Magiglo If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 15: ...important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertaint...

Страница 16: ...by a Gas Safe registered installer formerly CORGI within the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident...

Отзывы: