background image

Page

 

10

 

of

 

16

 

Light

 

the

 

fire

 

using

 

the

 

method

 

in

 

the

 

instructions

 

and

 

ensure

 

that

 

the

 

pilot

 

lights

 

consistently

 

and

 

the

 

pilot

 

flame

 

envelopes

 

the

 

thermocouple.

 

The

 

pilot

 

should

 

hold

 

in

 

10

 

seconds.

 

Turn

 

control

 

to

 

main

 

burner,

 

this

 

should

 

light

 

smoothly

 

within

 

10

 

seconds.

 

Ensure

 

the

 

valve

 

gives

 

adequate

 

turn

 

down

 

and

 

the

 

thermostat

 

bulb

 

reduces

 

the

 

burner

 

rate

 

to

 

off

 

when

 

heated.

 

The

 

gas

 

manifold

 

pressures

 

are

 

factory

 

preset

 

using

 

highly

 

accurate

 

equipment

 

and

 

may

 

be

 

observed

 

in

 

the

 

pressure

 

test

 

point

 

on

 

the

 

valve.

  

In

 

the

 

unlikely

 

event

 

of

 

the

 

pressure

 

being

 

incorrect

 

it

 

may

 

be

 

reset

 

(refer

 

to

 

dataplate

 

for

 

details),

 

using

 

a

 

manometer

 

or

 

other

 

pressure

 

testing

 

equipment.

   

Locate

 

thermostat

 

bulb

 

in

 

a

 

cool

 

place

 

away

 

from

 

the

 

appliance

 

and

 

preferably

 

outside

 

of

 

any

 

inglenooks,

 

to

 

ensure

 

it

 

is

 

sensing

 

room

 

air

 

temperature.

 

Run

 

appliance

 

for

 

10

 

minutes,

 

ensuring

 

burner

 

flames

 

settle

 

evenly.

 

A

 

combustion

 

analysis

 

check

 

should

 

then

 

be

 

carried

 

out.

 

Using

 

an

 

analyser

 

to

 

BS7927,

 

first

 

zero

 

the

 

equipment

 

and

 

sample

 

the

 

entire

 

width

 

of

 

the

 

combustion

 

product

 

outlet.

 

Ratio

 

of

 

CO/CO2

 

should

 

be

 

less

 

than

 

0.002

 

within

 

30

 

minutes.

 

(20ppm

 

CO

 

per

 

1%

 

CO2)

   

A

 

reading

 

of

 

CO

 

in

 

the

 

room

 

centre

 

should

 

give

 

a

 

rise

 

of

 

less

 

than

 

9ppm

 

over

 

ambient,

 

peak

 

reading.

 

The

 

catalyst

 

is

 

unlikely

 

to

 

need

 

replacement

 

during

 

the

 

life

 

of

 

the

 

heater

 

but

 

if

 

the

 

combustion

 

is

 

suspect,

 

disconnect

 

the

 

appliance

 

and

 

contact

 

the

 

manufacturer.

 

See

 

the

 

additional

 

information

 

on

 

testing

 

found

 

on

 

pages

 

13

 

&

 

14.

 

 

12.

 

PARTS

 

LIST

 

 

Part

 

Part

 

No

 

 

Front

 

Ceramic

 

Coal

  

COA4241F

 

 

Rear

 

Ceramic

 

Coal

 

COA4241B

 

 

Front

 

Ceramic

 

Pebble

 

PEB4241F

 

 

Rear

 

Ceramic

 

Pebble

 

PEB4241B

 

 

OXY

 

NG

 

OXYP4

41

D

 

 

OXY

 

LPG

 

OXYP4

51

E

 

 

Glass

 

GLA4140

 

 

Grill

 

GRI4240

 

 

90mm

 

Freestanding

 

Spacer

 

SPACERKIT

 

 

Rechargeable

 

Battery

 

BAT4240

 

 

Remote

 

Handset

 

REM4240

 

 

 

 

 

 

USE

 

ONLY

 

GENUINE

 

REPLACEMENT

 

PARTS.

 

 

Parts

 

ordered

 

from

 

our

 

factory

 

will

 

normally

 

take

 

5

 

 

7

 

working

 

days

 

to

 

be

 

delivered.

 

An

 

‘Express

 

service’

 

is

 

available

 

upon

 

request

 

at

 

an

 

additional

 

cost.

 

 
 

Due

 

to

 

our

 

policy

 

of

 

continual

 

improvement

 

and

 

development

 

the

 

exact

 

accuracy

 

of

 

descriptions

 

and

 

illustrations

 

can

 

not

 

be

 

guaranteed.

 

 

Burley

 

Magiglo

 

are

 

the

 

only

 

company

 

to

 

bench

 

run

 

and

 

thoroughly

 

test

 

every

 

single

 

Flueless

 

gas

 

fire

 

it

 

produces.

 

Burley

 

Magiglo

 

is

 

in

 

the

 

unique

 

position

 

of

 

knowing

 

that

 

every

 

appliance

 

leaves

 

the

 

factory

 

in

 

perfect

 

working

 

order.

 

 

Содержание EMPATHY 16"

Страница 1: ...iances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 725570 Fax 44 0 1572 724390 e mail info magiglo co uk web www magiglo co uk MAG4240InstUser G20 31 Issue JUNE10 v1 TO OBTAIN YOUR F...

Страница 2: ...n Injector manual valve Elbow 92 300 Elbow 92 90 Injector remote Elbow 92 170 Elbow 92 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and...

Страница 3: ...o cubic metre m divide the room volume in cubic feet by 35 3 3 7 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting rooms basements which are...

Страница 4: ...rectly against a wall 4 3 The fire comes with a 60mm spacer fitted to the front trim we recommend that this spacer is left on as it will keep the surfaces of the fireplace cooler Any combustible mater...

Страница 5: ...small hearth 50mm deep will be required to support the fire front No other hearth is required For all other applications use the hearth sizes in 4 8 4 14 Closure plate tape and foam seals are unsuita...

Страница 6: ...e pushing gas pipes through walls seal the pipe ends to prevent debris entering the pipes 6 4 Drill and fit cable fixing positions in accordance with diagram or alternatively drill and fit screws thro...

Страница 7: ...he burner It is important for clean burning that the correct moulding is fitted in the correct place There must be a clear gap between the two sets of coals pebbles Always replace the glass after layi...

Страница 8: ...he pressure must still be within the tolerance of 1mb Now turn off all the other gas appliances and turn the fire down to pilot only the pressure must still be within the tolerance of 1mb If it is not...

Страница 9: ...essive exposure to these materials may cause temporary irritation to the eyes skin and respiratory tract consequently it makes sense to take care when handling these parts to ensure that the release o...

Страница 10: ...utlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room centre should give a rise of less than 9ppm over ambient peak reading The catalyst is u...

Страница 11: ...urpose made battery housing Note If the fire emits a beeping sound this is just the safety system priming itself Because the remote control uses battery power when in the stand by mode The battery wil...

Страница 12: ...r into a clearer position In the event of the fire not working check both of the above points before calling an engineer 5 To ignite the fire point the handset at the fire push and hold simultaneously...

Страница 13: ...the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least...

Страница 14: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Magiglo If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 15: ...important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertaint...

Страница 16: ...by a Gas Safe registered installer formerly CORGI within the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident...

Отзывы: