Page 26
3.3. Technical Data
Natural Gas Models
All 16” Models
(ME16T, ET16 and
EV16)
All 18” Models
(ME18T, ET18 and
EV18)
Nominal maximum heat input
6.9 kW (gross)
8.25 kW (gross)
Setting pressure (Cold)
5.6 mbar ±0.2 mbar
7.4 mbar ±0.2 mbar
Minimum heat Input
4.0 kW (gross)
4.0 kW (gross)
Minimum setting pressure
1.9 mbar ±0.2 mbar
1.9 mbar ±0.2 mbar
Gas
G20 (Natural Gas)
G20 (Natural Gas)
Injector Size
104
104
Gas inlet connection
8mm
8mm
Control valve
BM/Mertik GV34
BM/Mertik GV34
Pilot
SIT OxyPilot 9039
SIT OxyPilot 9039
Weight
4.0kg
4.5kg
LPG Gas Models
All 16” Models
(LME16T, LET16
and LEV16)
All 18” Models
(LME18T, LET18 and
LEV18)
Nominal maximum heat input
6.9 kW (gross)
9.0 kW (gross)
Setting pressure (Cold)
28.0 mbar ±1.0 mbar
30.0 mbar ±1.0 mbar
Minimum heat Input
4.0 kW (gross)
4.0 kW (gross)
Minimum setting pressure
10.0 mbar ±1.0 mbar
6.0 mbar ±1.0 mbar
Gas
G31 (LPG)
G31 (LPG)
Injector Size
CAT16 220
63
Gas inlet connection
8mm
8mm
Control valve
BM/Mertik GV34
BM/Mertik GV34
Pilot
SIT OxyPilot 9223
SIT OxyPilot 9223
Weight
4.0kg
4.5kg