Page 28
3.3 Technical Data
Natural Gas Models
Up to 14.5” Burner
Width
14.5” to 18” Burner
Width
Nominal maximum heat input
6.9 kW (gross)
8.25kW (gross)
Setting pressure (Cold)
5.6 mbar ±0.2 mbar
7.4 mbar ±0.2 mbar
Minimum heat Input
4.0 kW (gross)
4.0 kW (gross)
Minimum setting pressure
1.9 mbar ±0.2 mbar
1.9 mbar ±0.2 mbar
Gas
G20 (Natural Gas)
G20 (Natural Gas)
Injector Size
104 104
Gas inlet connection
8mm
8mm
Control valve
BM/Mertik GV Series
BM/Mertik GV Series
Pilot
SIT OxyPilot
SIT OxyPilot
Weight
3.0kg
4.5kg
LPG Models
Up to 14.5” Burner
Width
14.5” to 18” Burner
Width
Nominal maximum heat input
6.9 kW (gross)
9.0kW (gross)
Setting pressure (Cold)
28 mbar ±1.0 mbar
30 mbar ±1.0 mbar
Minimum heat Input
4.0 kW (gross)
4.0 kW (gross)
Minimum setting pressure
10 mbar ±1.0 mbar
6 mbar ±1.0 mbar
Gas
G31 (LPG)
G31 (LPG)
Injector Size
CAT16 220
63
Gas inlet connection
8mm
8mm
Control valve
BM/Mertik GV Series
BM/Mertik GV Series
Pilot
SIT OxyPilot
SIT OxyPilot
Weight
3.0kg
4.5kg