508197-01
Issue 2137
Page 9 of 22
Model
Gas Heating
Indoor
Blower
Speed
0.1 “w.c.
0.2 “w.c.
0.3 “w.c.
0.4 “w.c.
0.5 “w.c.
Rise
Range
(F°)
Mid
Rise
(F°)
SCFM
W
atts
HP
Temp Rise
SCFM
W
atts
HP
Temp Rise
SCFM
W
atts
HP
Temp Rise
SCFM
W
atts
HP
Temp Rise
SCFM
W
atts
HP
Temp Rise
1 T
on
15MGE4-12-121*P
15 - 45
30
TAP 1
(FAN)
415 39 0.05
---
350 43 0.06
---
285 47
0.06
---
240 51
0.07
---
165 54 0.07
---
TAP 2
(COOL)† 425 46 0.06
---
370 49 0.07
---
315 53
0.07
---
N/A N/A N/A
---
N/A N/A N/A
---
TAP 3
(COOL) N/A N/A N/A
---
N/A N/A N/A
---
475 93
0.12
---
430 97
0.13
---
385 101 0.14
---
TAP 4
(HEAT)* 370 36 0.05
30 315 39 0.05
35 260 42
0.06
43 N/A N/A N/A
N/A N/A N/A N/A N/A
TAP 5
(HEAT)
N/A N/A N/A N/A N/A N/A N/A N/A 470 80
0.11
24 415 85
0.11
27 370 89 0.12
30
24MGE4-12-121*P
25 - 55
40
TAP 1
(FAN)
415 39 0.05
---
350 43 0.06
---
285 47
0.06
---
240 51
0.07
---
165 54 0.07
---
TAP 2
(COOL)† 425 46 0.06
---
370 49 0.07
---
315 53
0.07
---
N/A N/A N/A
---
N/A N/A N/A
---
TAP 3
(COOL) N/A N/A N/A
---
N/A N/A N/A
---
475 93
0.12
---
430 97
0.13
---
385 101 0.14
---
TAP 4
(HEAT)* 450 50 0.07
40 405 53 0.07
44 355 57
0.08
50 N/A N/A N/A
N/A N/A N/A N/A N/A
TAP 5
(HEAT)
N/A N/A N/A N/A N/A N/A N/A N/A 525 101 0.14
34 485 105 0.14
37 450 110 0.15
40
36MGE4-12-121*P
30 - 60
45
TAP 1
(FAN)
415 39 0.05
---
350 43 0.06
---
285 47
0.06
---
240 51
0.07
---
165 54 0.07
---
TAP 2
(COOL)† 425 46 0.06
---
370 49 0.07
---
315 53
0.07
---
N/A N/A N/A
---
N/A N/A N/A
---
TAP 3
(COOL) N/A N/A N/A
---
N/A N/A N/A
---
475 93
0.12
---
430 97
0.13
---
385 101 0.14
---
TAP 4
(HEAT)* 590 87 0.12
45 555 91 0.12
48 515 96
0.13
52 475 100 0.134
56 N/A N/A N/A N/A
TAP 5
(HEAT)
N/A N/A N/A N/A 680 138 0.19
39 650 143 0.19
41 615 148 0.198
44 585 153 0.21
46
1.5 T
on
15MGE4-12-181*P
15-45
30
TAP 1
(FAN)
470 54 0.07
---
400 59 0.08
---
345 63
0.08
---
290 67
0.09
---
235 70 0.09
---
TAP 2
(COOL)† 670 118 0.16
---
625 123 0.16
---
565 131 0.18
---
525 136 0.18
---
N/A N/A N/A N/A
TAP 3
(COOL) N/A N/A N/A
---
765 184 0.25
---
730 191 0.26
---
675 201 0.27
---
630 206 0.28
---
TAP 4
(HEAT)* 370 39 0.05
30 305 43 0.06
37 250 46
0.06
45 N/A N/A N/A
N/A N/A N/A N/A N/A
TAP 5
(HEAT)
N/A N/A N/A N/A N/A N/A N/A N/A 460 92
0.12
24 415 96
0.13
27 370 101 0.14
30
24MGE4-12-181*P
25-55
40
TAP 1
(FAN)
470 54 0.07
---
400 59 0.08
---
345 63
0.08
---
290 67
0.09
---
235 70 0.09
---
TAP 2
(COOL)† 670 118 0.16
---
625 123 0.16
---
565 131 0.18
---
525 136 0.18
---
N/A N/A N/A N/A
TAP 3
(COOL) N/A N/A N/A
---
765 184 0.25
---
730 191 0.26
---
675 201 0.27
---
630 206 0.28
---
TAP 4
(HEAT)* 450 52 0.07
40 385 57 0.08
46 330 61
0.08
54 N/A N/A N/A
N/A N/A N/A N/A N/A
TAP 5
(HEAT)
N/A N/A N/A N/A N/A N/A N/A N/A 540 116 0.16
33 490 121 0.16
37 450 127 0.17
40
36MGE4-12-181*P
30-60
45
TAP 1
(FAN)
470 54 0.07
---
400 59 0.08
---
345 63
0.08
---
290 67
0.09
---
235 70 0.09
---
TAP 2
(COOL)† 670 118 0.16
---
625 123 0.16
---
565 131 0.18
---
525 136 0.18
---
N/A N/A N/A N/A
TAP 3
(COOL) N/A N/A N/A N/A 765 184 0.25
---
730 191 0.26
---
675 201 0.27
---
630 206 0.28
---
TAP 4
(HEAT)* 590 86 0.12
45 555 90 0.12
48 515 95
0.13
52 475 99
0.13
56 N/A N/A N/A N/A
TAP 5
(HEAT)
715 129 0.17
38 680 135 0.18
39 650 140 0.19
41 615 146 0.20
44 585 151 0.20
46
N/A: Do not operate unit using this blower speed at this external static pressure.
† As shipped speed for Cooling operation. Blower speed must be field adjusted to speed Tap 3 for higher duct static applications.
* As shipped speed for Heating operation. Blower speed must be field adjusted to speed Tap 5 for higher duct static applications.
# As shipped speed for Low Stage Cooling operation (low duct static).
Table 4. Blower Performance (208V or 230V)
Содержание MGE4-12 Series
Страница 20: ...Page 20 of 22 508197 01 Issue 2137 Figure 12 Wiring Diagram MGE 0 75 Ton through 2 Ton Wiring Diagrams ...
Страница 21: ...508197 01 Issue 2137 Page 21 of 22 Figure 13 Wiring Diagram MGE 2 5 Ton ...
Страница 22: ...Page 22 of 22 508197 01 Issue 2137 Figure 14 Wiring Diagram MGE 3 Ton ...