3.5
SETUP MULTIPLE MACHINES IN A SEQUENCE WITH DMX
PowerCon TRUE1 female
PowerCon TRUE1 male
POWER
POWER IN
POWER OUT
POWER IN
POWER OUT
5-pole female
DMX IN
DMX OUT
DMX IN
DMX OUT
5-pole male
DMX
1.
Connect a power link cable to the power output.
2.
Connect the other end to the power input of the next machine.
3.
Connect a DMX cable to the DMX output.
4.
Connect the other end to the DMX input of the next machine.
5.
Use the buttons or a RDM controller to assign DMX addresses, see Chapter 1.
6.
Repeat step 1 to 5 for each subsequent machine.
NOTICE
Always plug in a DMX Terminator into the DMX output of the final
unit in the control sequence. Using a DMX Terminator improves
signal reliability.
CAUTION
Do not connect more units to a single electrical circuit than the
installed fuse is able to handle. (Calculate the summed load with
the electrical data from Chapter 1)