Magic-Pak V Series Скачать руководство пользователя страница 10

Page 10 of 21

507389-01

Issue 1504

SCFM

Temp

Rise

(F°)

SCFM

Temp

Rise

(F°)

SCFM

Temp

Rise

(F°)

SCFM

Temp

Rise

(F°)

TAP 1 (HEAT) *

208 or 230

455

42

415

46

385

50

355

54

TAP 2 (HEAT)

208 or 230

570

34

540

36

510

38

485

40

TAP 3 (HEAT)

208 or 230

655

29

625

31

595

32

575

33

TAP 4 (COOL)

208 or 230

410

370

340

305

TAP 5 (COOL)

208 or 230

455

415

385

355

TAP 1 (HEAT)

208 or 230

455

63

415

N/A

385

N/A

355

N/A

TAP 2 (HEAT) *

208 or 230

570

50

540

53

510

56

485

59

TAP 3 (HEAT)

208 or 230

655

44

625

46

595

48

575

50

TAP 4 (COOL)

208 or 230

410

370

340

305

TAP 5 (COOL)

208 or 230

455

415

385

355

TAP 1 (HEAT) *

208 or 230

630

45

600

48

570

50

550

52

TAP 2 (HEAT)

208 or 230

770

37

740

39

715

40

690

42

TAP 3 (HEAT)

208 or 230

885

32

855

34

830

35

810

35

TAP 4 (COOL)

208 or 230

605

575

545

520

TAP 5 (COOL)

208 or 230

650

615

585

555

TAP 1 (HEAT)

208 or 230

630

61

600

64

570

N/A

550

N/A

TAP 2 (HEAT) *

208 or 230

770

50

740

52

715

54

690

56

TAP 3 (HEAT)

208 or 230

885

43

855

45

830

46

810

47

TAP 4 (COOL)

208 or 230

605

575

545

520

TAP 5 (COOL)

208 or 230

650

615

585

555

TAP 1 (HEAT)

208 or 230

630

N/A

600

N/A

570

N/A

550

N/A

TAP 2 (HEAT)

208 or 230

770

61

740

64

715

66

690

68

TAP 3 (HEAT) *

208 or 230

885

53

855

55

830

57

810

58

TAP 4 (COOL)

208 or 230

605

575

545

520

TAP 5 (COOL)

208 or 230

650

615

585

555

TAP 1 (HEAT) *

208 or 230

645

44

615

47

590

49

565

51

TAP 2 (HEAT)

208 or 230

780

37

755

38

730

39

710

40

TAP 3 (HEAT)

208 or 230

900

32

875

33

855

34

835

34

TAP 4 (COOL)

208 or 230

800

775

755

735

TAP 5 (COOL)

208 or 230

880

860

835

815

TAP 1 (HEAT)

208 or 230

645

59

615

62

590

65

565

N/A

TAP 2 (HEAT) *

208 or 230

780

49

755

51

730

52

710

54

TAP 3 (HEAT)

208 or 230

900

43

875

44

855

45

835

46

TAP 4 (COOL)

208 or 230

800

775

755

735

TAP 5 (COOL)

208 or 230

880

860

835

815

TAP 1 (HEAT)

208 or 230

645

73

615

N/A

590

N/A

565

N/A

TAP 2 (HEAT)

208 or 230

780

61

755

63

730

65

710

67

TAP 3 (HEAT) *

208 or 230

900

53

875

54

855

55

835

57

TAP 4 (COOL)

208 or 230

800

775

755

735

TAP 5 (COOL)

208 or 230

880

860

835

815

TAP 1 (HEAT)

208 or 230

735

52

700

55

670

57

640

60

TAP 2 (HEAT) *

208 or 230

825

46

795

48

770

50

745

51

TAP 3 (HEAT)

208 or 230

895

43

865

44

840

46

810

47

TAP 4 (COOL)

208 or 230

800

765

735

715

TAP 5 (COOL)

208 or 230

880

845

820

795

TAP 1 (HEAT)

208 or 230

735

64

700

68

670

71

640

74

TAP 2 (HEAT)

208 or 230

825

57

795

59

770

61

745

63

TAP 3 (HEAT) *

208 or 230

895

53

865

55

840

56

810

58

TAP 4 (COOL)

208 or 230

800

765

735

715

TAP 5 (COOL)

208 or 230

880

845

820

795

-

HWC9N5511P30A

45

60

- 75

HWC9N4411P18A

HWC9N4411P30A

35

35 - 65

50

HWC9N5511P18A

45 - 75

60

HWC9N3311P18A

30 - 60

45

HWC9N5511P24A

45 - 75

35

55

40

65

50

- 65

50

0.4 " w.c.

HWC9N2211P12A

25 -

HWC9N3311P12A

Model

Rise

Range

(F°)

Mid

Rise

(F°)

Indoor Blower 

Speed

AIRFLOWS AND HEATING TEMPERATURE RISES

AS A FUNCTION OF EXTERNAL STATIC PRESSURE

0.2 " w.c.

0.3 " w.c.

Unit

Voltage

(V)

0.1 " w.c.

65

50

60

HWC9N4411P24A

35 -

N/A: Do not operate unit in heating mode using this blower speed at this external static pressure.  Outside of temperature rise range.
* : As shipped speed for heating operation

Table 2

HWC9N3311P24A

30 - 60

45

Table 2

Содержание V Series

Страница 1: ...not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Such actions could result in property damage personal injury or death WARNING Installati...

Страница 2: ...nit must be permanently installed per these installation instructions A room thermostat must control the furnace The use of fixed jumpers that will provide continuous heating is not allowed The return...

Страница 3: ...s must be installed in the system and must be maintained during construction Air filters must be replaced upon construction completion The input rate and temperature rise must be set per the furnace r...

Страница 4: ...Be certain that the plastic drain tube has free drainage and is not crimped or flattened at any bend Installing Without a Wall Sleeve Refer to the following directions and Figure 1 for guidance in in...

Страница 5: ...ent weld piping to street elbow Furnace condensate drain component locations Side exit Condensate Trap Side panel Upper Drain hose From Collector box Lower drain hose To drain fitting reposition and r...

Страница 6: ...ecuring the drain fitting to the division panel 3 Remove the drain fitting and rotate it so that it faces the front of the furnace 4 Replace the securing screw 5 Disconnect lower drain hose from drain...

Страница 7: ...ps for each appliance connected to the common venting system 7 After it has been determined that each appliance remaining connected to the common venting system properly vents when tested as outlined...

Страница 8: ...dition for installations in Canada See rating plate for correct wire ampacity for the cooling chassis required and size wire accordingly The furnace must be isolated from the gas supply piping system...

Страница 9: ...sure vary more than 0 3 W C for natural gas or 0 7 W C for propane To adjust the regulator turn the adjusting screw on the regulator clockwise to increase pressure and input or counterclockwise to dec...

Страница 10: ...835 34 TAP 4 COOL 208 or 230 800 775 755 735 TAP 5 COOL 208 or 230 880 860 835 815 TAP 1 HEAT 208 or 230 645 59 615 62 590 65 565 N A TAP 2 HEAT 208 or 230 780 49 755 51 730 52 710 54 TAP 3 HEAT 208 o...

Страница 11: ...could result in safety shutdown of the burners 1 Adjust to the highest achievable temperature rise within the rise and static pressure ranges specified on the rating plate Depending on specific model...

Страница 12: ...nce will try again Blower Control The blower will start approximately 30 seconds after the burners ignite and will stop approximately 120 seconds after the thermostat is satisfied The time delay is pr...

Страница 13: ...rnace be inspected annually by a qualified service person Inducer prover switch Ignition Control board Remove these screws to remove Burner Assembly Igniter Combustion Inducer Gas Valve Gas Manifold R...

Страница 14: ...efer to Figure 8 Remove the two screws on the burner assembly that secure it to the mounting brackets The mounting brackets contain pins to locate the assembly and hold it in place after the screws ar...

Страница 15: ...Page 15 of 21 507389 01 Issue 1504 BURNER MANIFOLD ASSEMBLY REMOVAL Step 7 Mounting Brackets Step 8 Step 9 Step 10 Burner Manifold Assembly Figure 8...

Страница 16: ...t without removing any other components To remove the rollout switch 1 Disconnect electrical service and turn off gas to the appliance 2 Disconnect the orange leads at the rollout switch 3 Remove the...

Страница 17: ...Page 17 of 21 507389 01 Issue 1504 Ignition board Bracket removal Tabs on Cold End Header box Figure 9 Press down on locking tab then slide bracket Slots on ignition board bracket...

Страница 18: ...e unit carefully pry the round portion of the orifice from the inducer inlet 3 Remove the indicator tab from the inducer mounting foot Model Orifice color HWC9N22 Blue HWC9N33 Black HWC9N44 Gray HWC9N...

Страница 19: ...assis normally requires no maintenance since it is a closed self contained system System is charged with R410A refrigerant Periodic maintenance is limited to Cleaning the air filter Follow directions...

Страница 20: ...Page 20 of 21 507389 01 Issue 1504 Figure 11...

Страница 21: ...Page 21 of 21 507389 01 Issue 1504 NOTES...

Отзывы: