507858-01
Issue 1922
Page 11 of 21
Model
Gas Heating
Indoor
Blower
Speed
0.1 “w.c.
0.2 “w.c.
0.3 “w.c.
0.4 “w.c.
0.5 “w.c.
Rise
Range
(F°)
Mid
Rise
(F°)
SCFM
W
atts
Temp
Rise
SCFM
W
atts
Temp
Rise
SCFM
W
atts
Temp
Rise
SCFM
W
atts
Temp
Rise
SCFM
W
atts
Temp
Rise
2.5 T
on
24MGE4-1
1-301*P
25-55
40
TAP 1
(FAN)
490
55
---
465
65
---
435
72
---
415
81
---
390
89
---
TAP 2
(COOL)†
930
239
---
900
243
---
885
250
---
835
256
---
805
262
---
TAP 3
(COOL)
1030 309
---
995
316
---
965
321
---
930
325
---
900
328
---
TAP 4
(HEAT)*
450
47
40
400
49
45
350
53
51
N/A
N/A N/A
N/A
N/A N/A
TAP 5
(HEAT)
N/A
N/A N/A
N/A
N/A N/A
530
93
34
490
98
37
450
103
40
36MGE4-1
1-301*P
30-60
45
TAP 1
(FAN)
490
55
---
465
65
---
435
72
---
415
81
---
390
89
---
TAP 2
(COOL)†
930
239
---
900
243
---
885
250
---
835
256
---
805
262
---
TAP 3
(COOL)
1030 309
---
995
316
---
965
321
---
930
325
---
900
328
---
TAP 4
(HEAT)*
600
80
45
560
84
48
515
89
52
475
93
56
N/A
N/A N/A
TAP 5
(HEAT)
N/A
N/A N/A
705
136
38
670
141
40
635
146
42
600
151
45
48MGE4-1
1-301*P
35-65
50
TAP 1
(FAN)
490
55
---
465
65
---
435
72
---
415
81
---
390
89
---
TAP 2
(COOL)†
930
239
---
900
243
---
885
250
---
835
256
---
805
262
---
TAP 3
(COOL)
1030 309
---
995
316
---
965
321
---
930
325
---
900
328
---
TAP 4
(HEAT)*
715
140
50
670
146
53
630
152
57
590
159
61
N/A
N/A N/A
TAP 5
(HEAT)
N/A
N/A N/A
815
218
44
775
227
46
740
233
48
705
241
51
60MGE4-1
1-301*P
40-70
55
TAP 1
(FAN)
490
55
---
465
65
---
435
72
---
415
81
---
390
89
---
TAP 2
(COOL)†
930
239
---
900
243
---
885
250
---
835
256
---
805
262
---
TAP 3
(COOL)
1030 309
---
995
316
---
965
321
---
930
325
---
900
328
---
TAP 4
(HEAT)*
810
163
55
775
169
58
740
173
60
710
179
63
680
185
66
TAP 5
(HEAT)
935
233
48
900
240
50
870
245
52
835
254
53
810
257
55
N/A: Do not operate unit using this blower speed at this external static pressure.
† As shipped speed for Cooling operation. Blower speed must be field adjusted to speed Tap 3 for higher duct static applications.
* As shipped speed for Heating operation. Blower speed must be field adjusted to Speed Tap 5 for higher duct static applications.
Table 4.
Blower Performance (208V or 230V)