12
GAS CONVERSION
WARNING
: Explosion Hazard
•
Use a new CSA International approved gas supply line�
•
Install a shut-off valve�
•
Securely tighten all gas connections�
•
If connected to LP, have a qualified person make sure gas pressure does not exceed 14” (36cm) water column�
•
Examples of a qualified person include: licensed heating personnel, authorized gas company personnel, and
authorized service personnel�
•
Failure to do so can result in death, explosion, or fire�
The range can be used with Natural Gas or LP/Propane Gas� The range is manufactured from the factory for use
with Natural Gas� A kit for converting to LP/Propane Gas is supplied with your cooktop� The kit is marked “For LP/
Propane Gas Conversion”�
NOTE
: When the cooktop is converted for LP/Propane Gas, the LP gas supply is required to provide a minimum
of 10” to a maximum of 14” water column to the cooktop regulator�
The conversion must be performed by a qualified service technician in accordance with the kit instructions and
all local codes/requirements�
CAUTION
: Failure to follow instructions could result in serious injury�
Parts Required
figure 12
7mm Nut Driver
Small Flat-Head Screwdriver
(2 to 2�4 mm or 3/32” tip
size, 60 mm long)
Wrench
Safety Glasses
Converting to LP/Propane Gas
burner Type
Max Output
Min Output
Natural Gas
LPG
kw
kw
Nozzle
(mm)
Cons
(M
3
/h)
Nozzle
(mm)
Cons
(g/h)
Auxiliary burner
1
0�3
1 x 1�10
0�1
1 x 0�70
73
Semi-Rapid burner
2
0�55
1 x 1�20
0�19
1 x 0�80
124
Triple Ring burner
4�5
1�5
5 x ø0�99
0�43
5 x ø0�56
327
figure 13
figure 14
Manual Shut-Off Valve
“Closed” Position
To Range
Gas Supply Line
1�
Turn the manual
shut-off valve to
the closed position�
(Refer to Figure 13�)
2�
Unplug range or
disconnect power�
3�
Unscrew the regulator
cap with the wrench�
(Refer to Figure 14�)
Retainer Pin
Regulator
Retulator Cap