8
The opening must be constructed so that
it will not be obstructed from inside or
outside, or constructed close to the floor.
The opening is recommended to be on the
side opposite to that on which the flue gases
are discharged.
Avoid placing cabinetry directly above
cooktop when possible. If cabinetry is used
above cooking surface, use cabinet no more
than 13” deep.
Working areas adjacent to the cooktop
should have a 18” minimum clearance
between countertop and cabinet bottom.
Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand
heat (up to 200°F) generated by the cooktop.
18.0” (457 mm)
min.
30.0” (762 mm) min.
13.0”
(330 mm)
max.
Figure 4
Figure 5
Maintain 30” minimum clearance between cooktop surface and cabinets installed above the cooktop.
- If a range hood is installed above the cooktop, it is important that the 30” minimum clearance between
the cooktop and bottom of the range hood is maintained. The range hood must be connected directly
to flues or to the outside.
- A range hood with minimum 350 CFM that projects at least 5” beyond front of cabinets can reduce risk
of burns caused by reaching over heated surface units.
GAS AND ELECTRICAL SUPPLY REQUIREMENTS
Installation must comply with local codes. In the absence of local codes, the gas cooktop must comply with the
National Fuel Gas Code ANSI Z223.1- latest edition in the United States, or in Canada CAN/CGA B149.1 and CAN/
CGA B149.2 and the National Electrical Code ANSI/NFPA No.70 – latest edition in United States, or in Canada CSA
Standard C22.1, Canadian Electrical Code, Part 1, and local code requirements.
1.0” (26 mm) min.
12.0” (305 mm)
Gas Supply
Line
Gas Supply Requirements
The gas supply should be located near the opening for
this cooktop and a minimum of 1” from the back wall. This
cooktop is manufactured for natural gas and is designed
to operate at 5” water column pressure. The regulator is
required to provide a minimum of 6” water column to a
maximum of 14” water column to the cooktop regulator.
Electrical Supply Requirements
The electric spark ignition feature for this model requires
a 120V electrical power supply and should be located 12”
below the countertop and within reach of the cooktops
four-foot power cord.