Front Panel
Voyager Matrix Fiber Optic Switch
Installation and User Guide
9
4.6
Power St
atus Indicator (“Pilot Light”)
If power is off, the power up sequence will automatically be initiated when power is turned on. If a chassis has
been properly shut down with AC power left on (indicated by pilot light = amber), the power up sequence may be
initiated by pressing & holding the on/off switch for 6 seconds or more.
The unit will beep 4 times and the pilot light will turn green. If pilot light is not green, refer to the chart below for
possible trouble situations. If further assistance is required, please contact a Magenta customer service
representative.
COLOR
DESCRIPTION
Solid Green
System power is ON; no faults/alarms/warnings exist.
Flashing Red
System power is ON; faults/alarms/warnings exist.
Solid Amber
System Power is OFF; no faults/alarms/warnings exist.
Alternating Red & Amber
System power is OFF due a critical fault (like an emergency
shutdown from over temp).
Red then solid Amber
Power up sequence failed.
Alternating Red & Green
System power is ON after an “auto restart from fault” sequence
(this records an auto-start occurred when no operator was present).
4.7
Status Indicator Bar (“Dashboard”)
The DASHBOARD indicator provides additional system health information at a glance. It consists of 8 illuminated
legends, arranged as follows (left to right as shown):
The backlight behind each legend is a fully programmable R/G/B LED light source. In brief, the various legends
have these functionalities:
FAN = Fan status
COLOR
DESCRIPTION
Green
OK
Amber
WARNING: At least one fan-tach is reading slower than minimum RPM.
Red
FAULT: At least one fan-tach is reading 0 RPM (failed, or locked-rotor).
Red flashing
FAULT: Fan-tray not installed.
FILTER = Filter status
COLOR
DESCRIPTION
Green
OK
Amber
WARNING: Service interval indicates air-filter service is required.
Red
FAULT: Service interval exceeds set in 30 days.
Red flashing
FAULT: Air-filter not installed.
Pilot Light