Front Panel
Voyager Matrix Fiber Optic Switch
Installation and User Guide
8
4.4
Keylock Switch
The
Keylock switch
has 2 positions: OPERATE and LOCKED. The physical key is removable in either position.
This keylock switch is intended to prevent accidental tampering with the power button. When the TC option is
installed, it also prevents accidental switch routing changes. The keylock must be in the unlocked position to
enable full access to the front panel functions (including the TC).
Note that the keylock has no effect on the operation of the front-panel serial or USB ports.
The Voyager Matrix chassis comes with two (2) keys. If additional keys are needed please contact Magenta
Research at 800-805-0944 (USA only) or +1-860-210-0546.
4.5
Power / Control Switch (“Pushbutton”)
The
pushbutton
input functions somewhat like the front-
panel “power switch” on desktop PCs. It has some
additional functions and restrictions based on the state of the keylock input.
When Keylock Status = OPERATE
If pushbutton is pressed and released quickly (less than 6 seconds):
If the audible alarm is ON, then silence the alarm for 10 minutes.
Note: This does not affect the alarm relay output.
Initiate dashboard LED display test (quick red/green/blue sequence, 1 sec each color).
Initiate pilot LED test (quick red/green sequence, 1 sec each color).
Note: If previous pilot light status was flashing red/green (system auto-restarted), then
reset pilot light status to solid Green.
If pushbutton is pressed and held for 6 seconds or more:
This will initiate the main power down or power up sequence, as appropriate.
When Keylock Status = LOCKED
If pushbutton is pressed and released quickly (less than 6 seconds):
If the audible alarm is
on
, then silence the alarm for 10 minutes.
Note: This does not affect the alarm relay output.
Initiate dashboard LED display test (quick red/green/blue sequence, 1 sec each color).
Initiate pilot LED test (quick red/green sequence, 1 sec each color).
Note: If previous pilot light status was flashing red/green (system auto-restarted), then
reset pilot light status to solid Green.
If pushbutton is pressed and held for 6 seconds or more:
The main power down or power up sequences is
NOT
initiated.
OPERATE
LOCKED
Pushbutton
Switch