MAGENTA MULTIVIEW™ SERIES 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

© 1998-2008 by Magenta Research  All rights reserved. 

 
Magenta Research  
128 Litchfield Road 
New Milford, CT 06776  USA

 

This document and the Magenta Research  products to which it relates, and the copyright in each, is the property of 
Magenta Research. Neither the document nor the products may be reproduced by any means, in whole or in part, without 
the prior written permission of Magenta Research.  Magenta Research makes no warranty or representation, either 
express or implied, with respect to this software or documentation, including their quality, performance, merchantability, 
or fitness for a particular purpose.  As a result, this software or documentation are licensed "as is" and you, the licensee, 
are assuming the entire risk as to their quality and performance. 

In no event will Magenta Research be liable for direct, indirect, special, incidental, or consequential damages arising out of 
the use of or inability to use the software or documentation. 

 

Magenta Research and the Magenta Research logo are trademarks of Magenta Research. 
All other brands, product names, and trademarks are the property of their respective owners. 

 
 

FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY  
INTERFERENCE STATEMENTS 

 

This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict 
accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to 
comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, 
which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial 
environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own 
expense will be required to take whatever measures may be necessary to correct the interference. 
 
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate 
the equipment. 

 
This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio 
Interference Regulation of Industry Canada. 

 

EUROPEAN UNION DECLARATION OF CONFORMITY 

 

The manufacturer declares that this product meets the requirements of EU Directive 89/336/EEC. 
 

Содержание MultiView II AK600

Страница 1: ...1 MultiView AK600 Receiver Quick Reference Setup Guide Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com...

Страница 2: ...ty of their respective owners FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates uses and can radiate radio frequency energy and if...

Страница 3: ...on the Single Port VGA Audio 5 3 3 3 Connections on the Single Port RS232 version 6 3 3 4 Connections on the Single Port SA SAP version 7 3 4 Video Adjustment 8 3 4 1 Cable Distance Compensation Sett...

Страница 4: ...pedance Video IN 75 ohms Audio models Audio IN if any 600 ohms minimum SPDIF audio models 75 Ohm Audio Characteristics Right Left summed A option SA SAP Full Stereo Line Level 600 Ohm Unbalanced Seria...

Страница 5: ...intended for nor does it support distribution through an Ethernet network Do not connect these devices to any sort of networking or telecommunications equipment 2 2 Equipment You May Also Need Audio...

Страница 6: ...AP series are fixed at 9600 Simplex modes are supported without jumper or other changes by simply using the TX signal only See Appendix G on configuration and use of SAP Series 3 2 Cabling Considerati...

Страница 7: ...ideo should appear on the display make sure display is powered ON 4 To adjust video levels and skew compensation see Section 3 4 5 Please mount the AK600 in a location that ensures the ventilation hol...

Страница 8: ...s without serial communications Figure 3 3 shows the Single Port MultiView CAT5 Video System with RS 232 Transmitter connections and Figure 3 4 shows the receiver connections NOTE Even though both tra...

Страница 9: ...modes are not affected by this Serial signals are 3 wire RS232 Tx Rx ground and fixed at 9600 baud Full 9 pin modem signals are not supported Note when using the Magenta MultiView SA SAP series with...

Страница 10: ...the proper EQ setting resulting in picture loss To Reset EQ and Skew values to 0 remove power from AK600 Push and hold EQ Skew Knob in and re apply power 1 Push EQ Skew knob in once so that the R G B...

Страница 11: ...module is not installed call for technical assistance An image file is available to assist in these settings see Section 3 4 1 for details See Figure 3 8 for an example 1 To adjust individual colors...

Страница 12: ...tions The video signal s refresh rate may be set too high Reset to a lower refresh rate in your monitor configuration menu There may be a delay skew issue See Section on Skew Problem Poor audio qualit...

Страница 13: ...he standard video serial model is designed to function with DC coupled signals in which the black level is referenced to 0 volts Nearly all VGA cards function this way Some media servers however provi...

Страница 14: ...nel 2 for Right audio and channel 1 for Left audio Pin RGBHV VGA RGBS RGsB Composite SVHS Y C YUV 1 Red Red Red C V 2 Green Green Green C Y Y 3 Blue Blue Blue U 4 5 Gnd Gnd Gnd 6 Red Red Red C V 7 Gre...

Страница 15: ...inouts Appendix A Cabling Pinouts Table A 3 DB9 Male Serial connector Table A 4 T568B CAT5 pinout DB9 for RS232 Pin Full Duplex 3 wire SA SAP Simplex 1 DCD 2 RX RX 3 TX TX TX 4 DTR 5 Ground Ground Gro...

Страница 16: ...owing jumper location diagram as well as Table B 1 for jumper settings Figure B 1 AK600 Jumper locations AUTO SYNC MODES JP8 controls sync clamping circuitry and works with the external switch labeled...

Страница 17: ...3 OFF OFF OFF OFF OFF OFF OFF Composite S Video Component Video see note below on daisy chaining With Left Right Line Level Audio 1 2 1 2 1 2 1 2 OFF ON ON OFF OFF OFF OFF With SDPIF Digital Audio 1 2...

Страница 18: ...ure the unit is powered OFF 2 If necessary unplug all cables to the unit 3 Unscrew the top screw as well as the two set screws in the DB9 connector Lift the cover off Table C 1 shows the Transmitter S...

Страница 19: ...using Mode 5 Mode Type Baud Max JP1 JP2 1 Simplex one way to 1500 ft 115k 1 2 See Notes 3 4 See Notes 5 6 IN 7 8 OUT 9 10 OUT 1 2 IN 3 4 OUT 5 6 OUT 7 8 OUT 9 10 IN 2 Full Duplex 2 way Short 500 ft 19...

Страница 20: ...le to change at the video source 1080P signals may also require this mode if the sync is a very narrow pulse The following details jumper settings to change the sync polarity of the horizontal and ver...

Страница 21: ...pins 1 2 4 5 7 8 4 Insert the Skew assembly onto the PCB using 11 pin headers J16 and J17 5 The correct orientation of the skew board is to place the side with the Magenta logo into header J17 6 Reass...

Страница 22: ...unit on a wall Figure F 2 shows the 4 Unit Rackmount Bracket which holds four units in a 19 x 1U rack Not shown are brackets for 6 units and brackets for AK and XR series receivers T4 transmitters The...

Страница 23: ...is also recommended to keep a list of receiver addresses and locations to make it easier to determine which receiver display is desired to communicate with 1 Remove the top cover assembly of the rece...

Страница 24: ...24 MAGENTA MULTIVIEW SERIES 22 Appendix G Pollable Serial Mode Address Chart...

Страница 25: ...25 23 Appendix G Pollable Serial Mode Address Chart cont APPENDIX F Pollable Serial Mode...

Страница 26: ...26 MAGENTA MULTIVIEW SERIES 24 NOTES...

Страница 27: ...27 25 NOTES...

Страница 28: ...28 MAGENTA MULTIVIEW SERIES Magenta Research 128 Litchfield Road New Milford CT 06776 USA 860 210 0546 FAX 860 210 1758 www magenta research com PN 5310214 01 Rev 02 May 2008...

Отзывы: