M A I N T E N A N C E
Cell Maintenance
Our Clear Cell allows for easy regular inspections for calcium build up.
Check the Cell visually 4 times a year and clean if necessary.
Cell Cleaning
1. Turn off the control Box
2. Unplug the electrical connection from the Cell.
3. Disconnect the two - barrel unions and remove the Cell from the line.
4. Attach the Cell Cleaning Cap to one end of the cell.
5. Pour into the cell, either undiluted white distilled vinegar, or a
solution of diluted muriatic acid.
Wait for foaming action to stop (5 – 10 minutes)
6. Empty the Cell.
7. Re-install the Cell in the line with the o-rings back in place.
Reconnect the electrical connectors; be sure to firmly tighten the
screws.
CAUTION: Always add acid to water, NOT water to acid
Diluted muriatic solution acid: 10 parts water to 1 part acid
Note:
Follow the instructions of the acid manufacturer
.