background image

 

5

A D D I N G   S A L T  

 

Adding the salt:

 

Turn the Control Box OFF.  Failure to do so will cause the fuse to 
blow. 
Keep the pump on to circulate the water.   
Distribute the determined amount of salt evenly around the pool. It 
will take 8 hours for the salt to disperse evenly in the water.  
Once the salt has fully dissolved, adjust your chlorinator to your 
normal setting.  

 

 

 

A c t u a l   s a l t   L e v e l   –   i n   P P M  

 

 

 0 

500 

1000 1500 2000 2500 3000 3500 

4000 

 

 

 

How much salt to add - in kg 

 

 

10 40 35 30 25 20 15 10 5  0 
20 80 70 60 50 40 30 20 10 0 
30 120 

105 

90 75 60 45 30 15 0 

40 160 

140 

120 100 80 60 40 20 0 

50  200 175 150 125 100 75  50  25  0 
60  240 210 180 150 120 90  60  30  0 
70  280 245 210 175 140 105 70  35  0 
80  320 280 240 200 160 120 80  40  0 
90  360 315 270 225 180 135 90  45  0 
100

400 350 300 250 200 150 100 50  0 

110

440 385 330 275 220 165 110 55  0 

120

480 420 360 300 240 180 120 60  0 

130

520 455 390 325 260 195 130 65  0 

140

560 490 420 350 280 210 140 70  0 

150

600 525 450 375 300 225 150 75  0 

160

640 560 480 400 320 240 160 80  0 

170

680 595 510 425 340 255 170 85  0 

180

720 630 540 450 360 270 180 90  0 

190

760 665 570 475 380 285 190 95  0 

200

800 700 600 500 400 300 200 100 0 

 

 

 

Your

 poo

l wa

ter

 v

ol

um

e -

 in

 thous

a

nds

 of

 li

ter

Содержание PSC-3

Страница 1: ...The Natural Chlorine Generator OWNER S MANUAL Model PSC 3 MAGEN eco Energy Kibbutz Magen 85465 Israel June 2010 Phone 972 8 998 3053 Fax 972 8 998 3063 info magen ecoenergy com www magen ecoenergy com...

Страница 2: ...n a flat surface 2 Pole circuit devices must be used and a minimum of 1 5 m horizontal distance or more if local regulations require from the pool spa The power cable must be hardwired to the time clo...

Страница 3: ...ty First 2 OPERATION General 4 Water Basics 4 Adding Salt 5 Operating Instructions 6 INSTALLATION General 9 Installation instructions 9 Control Box 9 Cell 10 Flow Sensor 11 Wiring 12 MAINTENANCE Maint...

Страница 4: ...vel of free chlorine without drastic fluctuations in the chemical levels and chloramines that cause strong chlorine odors irritated eyes itchy skin and faded swimsuits C H E M I C A L B A L A N C E T...

Страница 5: ...50 40 30 20 10 0 30 120 105 90 75 60 45 30 15 0 40 160 140 120 100 80 60 40 20 0 50 200 175 150 125 100 75 50 25 0 60 240 210 180 150 120 90 60 30 0 70 280 245 210 175 140 105 70 35 0 80 320 280 240 2...

Страница 6: ...e To turn the unit off turn the Control Knob down counterclockwise until it reaches its end position Power Meter The lights indicate the system s chlorine output i e 10 to 100 production rate The high...

Страница 7: ...d Light above the Power Meter indicates that the salt level in the pool is on the high side This does not harm the Natural Generator but is provided as a cautionary notice to the user not to add more...

Страница 8: ...nking Power Light indicates that the system is ramping up the charge to the cell i e soft start This is a normal occurrence and the light should turn solid green within a couple of minutes A soft star...

Страница 9: ...on page 2 of this manual M o u n t t h e C o n t r o l B o x The Control Box must be mounted vertically on a flat surface 2 Pole circuit devices must be used and a minimum of 1 5 m horizontal distanc...

Страница 10: ...T in the return line Install the Cell either horizontally or vertically as needed Be sure the black o rings are firmly in place Make sure that the Cell is installed with the arrow pointing the direct...

Страница 11: ...sition the flow sensor before the Cell and If possible install on a horizontal pipe if installed after the Cell damage to the flow sensor may result Be sure the arrow on the top of the Flow Sensor is...

Страница 12: ...l Box cannot operate without the pump operating i e load side Hardwire the power cable 230 Volt to the time clock along with the pump s power so that the Control Box cannot operate without the pump op...

Страница 13: ...e Flow Sensor see previews page connectors no 1 Ensure that the connections are perfectly clean of any debris Connect the two black wires arriving from the Control Box to the two connectors at the sid...

Страница 14: ...e line 4 Attach the Cell Cleaning Cap to one end of the cell 5 Pour into the cell either undiluted white distilled vinegar or a solution of diluted muriatic acid Wait for foaming action to stop 5 10 m...

Страница 15: ...egular maintenance other than checking that the wiring between the Control Box and Cell is securely in place It is recommended to keep the Control Box clean dry and out of the sun The Power Meter Led...

Страница 16: ...stabilizer See Understanding the Chemistry 1 Chlorine level low or no chlorine Chemical imbalance Check other chemistry and balance chemicals See Understanding the Chemistry Chlorine level too low Co...

Страница 17: ...draining a significant amount of pool water and refilling the pool 5 Lights go up down quickly Short Circuit in cell cable Check that cell wires are properly fastened and there is no visible reason to...

Страница 18: ...icient or no water flow to Cell Cut wires or insufficient wire connections Check the connection to ensure proper wire contact Too much salt has been added causing the red light above the power meter t...

Страница 19: ...ice year Clean Cell as instructed in the Maintenance section 12 Scale build up inside Cell Chemical imbalance Balance chemicals Focus mostly on the Saturation Index in the section titled Understanding...

Отзывы: