Version 1.6
30 | System Programming
MG6250 • Section Programming Guide
Arming/Disarming Options
Wireless Module Options
Section
Option
Description
OFF
ON
[2002]
1
Volume boost on entry/exit
Disabled
Enabled
2
Volume boost in speaker phone mode
Disabled
Enabled
3
Check-in supervision time
24 Hrs.
80 minutes
4
RF jamming supervision
Disabled
Enable
5
Daylight savings time
Disabled
Enable
6
Trouble latch
Disabled
Enable
7
Need to code view troubles/events
Disabled
Enable
8
Bell squawk when installer enters programming
Disabled
Enable
Section
Option
Description
OFF
ON
[2003]
1
Bell squawk when arming/disarming with remote control
Disabled
Enabled
2
Stay arming switches to Force Stay arming
Disabled
Enabled
3
Sleep arming switches to Force Sleep arming
Disabled
Enabled
4
Full arming switches to Force Full arming
Disabled
Enabled
5
Report system disarming
Always
After alarm
only
6
One-touch Stay arming
Disabled
Enabled
7
One-touch Sleep arming
Disabled
Enabled
8
One-touch Full arming
Disabled
Enabled
Section
Option
Description
OFF
ON
[2004]
1
Future use
-
-
2
Report Zone restore
On bell cut-off
On zone closure
3 & 4
Tamper recognition options (console tamper follows this option)
3
4
Disabled
OFF
OFF
Trouble only
OFF
ON
Disarmed: Trouble only
Armed: Follow zone’s alarm type
ON
OFF
Disarmed: Audible alarm
Armed: Follow zone’s alarm type
ON
ON
5
Generate tamper trouble if detected on bypassed zone
Disabled
Enabled
6 & 7
Wireless transmitter supervision option
6
7
Disabled
OFF
OFF
Trouble only
OFF
ON
Disarmed: Trouble only
Armed: Follow zone’s alarm type
ON
OFF
Disarmed: Audible alarm
Armed: Follow zone’s alarm type
ON
ON
8
Generate supervision trouble if detected on bypassed zone
Disabled
Enabled
Section
Option
Description
OFF
ON
[2005]
1
Input/Output 1 used as
PGM 1
Zone 1
2
Input/Output 2 used as
PGM 2
Zone 2
3
PGM 1 normal state
N. O.
N. C.
4
PGM 2 normal state
N. O.
N. C.
5
Future use
-
-
6
Live display mode for wireless keypad
Disabled
Enabled
7
End-of-Line (EOL) resistor
No EOL
Use EOL resistor
8
Future use
-
-
Содержание MG6250
Страница 1: ...MG6250 2 Partition 64 Zone Wireless Console with GPRS GSM Version 1 6 Section Programming Guide ...
Страница 43: ...MG6250 Section Programming Guide Version 1 6 Entering Information 43 Figure 2 Russian Bulgarian Serbian ...
Страница 45: ...MG6250 Section Programming Guide Version 1 6 Entering Information 45 Figure 4 Greek ...
Страница 46: ...Version 1 6 46 Entering Information MG6250 Section Programming Guide Figure 5 Turkish ...
Страница 47: ...MG6250 Section Programming Guide Version 1 6 Entering Information 47 Figure 6 Hebrew ...
Страница 48: ...Version 1 6 48 Entering Information MG6250 Section Programming Guide Figure 7 Lithuanian Estonian Latvian ...