387 Intrusion detector Hi sensitivity

75

451 Early open/close

9A

603 Periodic RF transmission

BF

388 Intrusion detector Low 

sensitivity

76

452 Late open/close

9B

604 Fire test

C0

389 Sensor self-test failure

77

453 Failed to open

9C

605 Status report to follow

C1

391 Sensor watch trouble

78

454 Failed to close

9D

606 Listen-in to follow

C2

392 Drift compensation error

79

455 Auto-arm failed

9E

607 Walk test mode

C3

393 Maintenance alert

7A

456 Partial arm

9F

608 Periodic test  - system trouble 

present

C4

Open/Close - 400

457 Exit error (user)

A0

609 Video transmitter active

C5

400 Open/Close

7B

458 User on premises

A1

611 Point test OK

C6

401 Open/Close by user

7C

459 Recent close

A2

612 Point not tested

C7

402 Group open/close

7D

System - 460

613 Intrusion zone walk tested

C8

403 Automatic open/close

7E

461 Wrong code entry

A3

614 Fire zone walk tested

C9

404 Late to open/close

5E

462 Legal code entry

A4

615 Panic zone walk tested

CA

405 Deferred open/close

5F

463 Re-arm after alarm

A5

616 Service request

CB

406 Cancel

7F

464 Auto-arm time extended

A6

621 Event log reset

CC

407 Remote arm/disarm

80

465 Panic alarm reset

A7

622 Event log 50% full

CD

408 Quick arm

81

466 Service ON/OFF premises

A8

623 Event log 90% full

CE

409 Keyswitch open/close

82

Sounder Relay Disabled - 520

624 Event log overflow

CF

Remote Access - 410

520 Sounder/Relay disabled

A9

625 Time/Date reset

D0

411 Call back request made

83

521 Bell 1 disabled

AA

626 Time/Date inaccurate

D1

412 Success - download access

84

522 Bell 2 disabled

AB

627 Program mode entry

D2

413 Unsuccessful access

85

523 Alarm relay disabled

AC

628 Program mode exit

D3

414 System shutdown

86

524 Trouble relay disabled

AD

629 32-hour event log marker

D4

415 Dialer shutdown

87

525 Reversing relay disabled

AE

630 Schedule change

D5

416 Successful upload

88

526 Notification appliance chk. #3 

disabled

AF

631 Exception schedule change

D6

Access Control - 420 and 430

527 Notification appliance chk. #4 

disabled

B0

632 Access schedule change

D7

421 Access denied

89

Modules - 530

654 System inactivity

D8

422 Access report by user

8A

531 Module added

B1

423 Forced access

8B

532 Module removed

B2

424 Egress denied

8C

Communication Disables - 550 and 560

425 Egress granted

8D

551 Dialer disabled

B3

426 Access door propped open

8E

552 Radio transmitter disabled

B4

427 Access point door status 

monitor trouble

8F

Bypasses - 570

428 Access point request  to exit

90

570 Zone bypass

B5

429 Access program mode entry

91

571 Fire bypass

B6

430 Access program mode exit

92

572 24Hr. zone bypass

B7

431 Access threat level change

93

573 Burglary bypass

B8

432 Access relay/trigger fail

94

574 Group bypass

B9

433 Access RTE shunt

95

575 Swinger bypass

BA

434 Access DSM shunt

96

576 Access zone shunt

BB

Arming - 440 and 450

577 Access point bypass

BC

441 Armed Stay

97

Test/Misc. - 600

442 Keyswitch armed Stay

98

601 Manual trigger test

BD

450 Exception open/close

99

602 Periodic test report

BE

CID#

Reporting Code

Programming 
Value

CID#

Reporting Code

Programming 
Value

CID#

Reporting Code

Programming 
Value

Содержание MG-6030

Страница 1: ...Programmable Outputs PGMs 5 System Options 5 Communicator Settings 8 Report Codes 9 Remote Control Button Programming 10 System Settings 11 Wireless Programmable Output PGM Settings 12 Appendix 1 PGM...

Страница 2: ...it can be any value from 0 to 9 See section 182 on page 11 to change the default code Master Code Default 1234 123456 With the System Master code a user can use any arming method and can program user...

Страница 3: ...nLoad Software Will force the console to answer an incoming call from the monitoring station that is using the WinLoad software Key 4 Call WinLoad Software Will dial the PC telephone number programmed...

Страница 4: ...ell cut off time 004 mins 064 ____ ____ ____ x 15 minutes No movement time Disabled 065 ____ ____ ____ seconds minimum 10 seconds Intellizone delay 045 secs 066 ____ ____ ____ seconds Recent closing d...

Страница 5: ...Silent or audible alarm Silent Audible 6 Panic 3 Silent or audible alarm Silent Audible 7 PGM1 used as MG 6060 only Direct output X10 output 7 8 PGM2 used as MG 6060 only Direct output X10 output 8 09...

Страница 6: ...n trouble if detected on bypassed zone No Yes 095 Zone Options Bold Default setting Option OFF ON 1 Zone 15 is hardwire zone 1 Disabled Enabled 2 Zone 16 is hardwire zone 2 Disabled Enabled 3 EOL End...

Страница 7: ...se Alarm Alarm Restore Report Codes 5 Call monitoring station telephone number 1 Disabled Enabled 6 Call monitoring station telephone number 2 Disabled Enabled 7 Call Pager telephone number Disabled E...

Страница 8: ...eport format for monitoring station telephone number 2 107 ____ ____ ____ ____ Account number 108 ____ ____ ____ ____ Panel identifier for use with WinLoad software 109 ____ ____ ____ ____ Panel passw...

Страница 9: ...____ ____ User Code 12 123 ____ ____ User Code 13 129 ____ ____ User Code 13 ____ ____ User Code 14 ____ ____ User Code 14 ____ ____ User Code 15 ____ ____ User Code 15 ____ ____ User Code 16 ____ __...

Страница 10: ...Zone 6 ____ ____ Fail to comm ____ ____ Future use ____ ____ Installer logout ____ ____ Zone 7 ____ ____ TX low battery ____ ____ TX low battery ____ ____ Delinquency ____ ____ Zone 8 ____ ____ TX su...

Страница 11: ...165 5 ______ ______ ______ ______ 173 13 ______ ______ ______ ______ 166 6 ______ ______ ______ ______ 174 14 ______ ______ ______ ______ 167 7 ______ ______ ______ ______ 175 15 ______ ______ ______...

Страница 12: ...ent programmed 216 PGM4 Activation Event ____ ____ ____ ____ No event programmed 217 PGM4 Deactivation Event ____ ____ ____ ____ No event programmed Section 218 Wireless PGM Supervision Options Bold D...

Страница 13: ...e center keypad 14 Utility Key 2 pressed keys 2 and 10 from the center keypad 15 Utility Key 3 pressed keys 3 and 11 from the center keypad 16 Utility Key 4 pressed keys 4 and 12 from the center keypa...

Страница 14: ...gency 01 Panic medical this medical panic alarm is not UL approved 02 Panic fire 03 Recent closing 04 Global shutdown 05 Duress alarm User 16 99 Any special alarm event 25 Zone shutdown 01 to 16 Zone...

Страница 15: ...d 43 PGM supervision lost 44 PGM supervision restored 45 PGM tampered 46 PGM tamper restored 01 to 04 PGM number 99 Any PGM number 47 Future use Future use 48 Fire delay started 01 to 16 Zone number 9...

Страница 16: ...res into the AC terminals Back view of the Magellan console 12Vdc to 18Vdc 1A Insert the transformer s wires into the AC terminals DC Power Supply Backview of the Magellan console Insert the backup ba...

Страница 17: ...and ahead of all other equipment attached to the same telephone line Proper installation is depicted in the diagram below If you have any questions concerning these instructions you should consult you...

Страница 18: ...the Radio Antenna MG 6060 only Figure 9 Connecting the Radio Antenna Back view of the Magellan console If the radio reception is not very good connect the supplied radio antenna to the ANT terminal of...

Страница 19: ...RJ 11 cable into the X10 plug of the console 2 Connect the other end of the inverted 4 pin RJ 11 cable into the X10 transmitter 3 Plug the X10 transmitter into a standard wall outlet 1 2 3 Do not con...

Страница 20: ...n will begin downloading the data from the memory key Copy Data to Memory Key from Source Console To copy the contents of a console into the memory key 1 Remove power from the Magellan console AC and...

Страница 21: ...e used to raise the Magellan console to a slight angle for easy viewing while the rubber stops prevent the console from sliding when Magellan is being used Tabletop mounting may not be an approved ins...

Страница 22: ...352 Telco 2 fault 5F 125 Duress Egress granted 12 System Troubles 300 and 310 353 Long range radio 60 Burglar Alarms 130 300 System trouble 39 354 Fail to communicate 61 130 Burglary 13 301 AC loss 3A...

Страница 23: ...521 Bell 1 disabled AA 626 Time Date inaccurate D1 412 Success download access 84 522 Bell 2 disabled AB 627 Program mode entry D2 413 Unsuccessful access 85 523 Alarm relay disabled AC 628 Program mo...

Страница 24: ...Open by user OR Disarm from Alarm Cancel alarm with User Code 1 4A6 Open by user OR Disarm from Alarm Cancel alarm with Keyswitch 1 4A6 Keyswitch Open OS Opening Keyswitch Auto Arming Cancellation 1 4...

Страница 25: ...attery Trouble Module Auxiliary supply trouble 1 3AA System trouble YP Power Supply Trouble Bus fault restore 3 333 Expansion module failure restore ER Expansion Restoral Module tamper restore 3 145 E...

Страница 26: ...e product Seller s warranty as hereinabove set forth shall not be enlarged diminished or affected by and no obligation or liability shall arise from Seller offering to render or rendering technical ad...

Страница 27: ......

Страница 28: ...ring volume ring tone 9 demo mode on time on zone open remote button on exit delay when armed on entry delay on alarm house code Must enter the installer maintenance or user code to access Master Cod...

Отзывы: