Intended use

GENERAL CONSIDERATIONS

Before Using

•  Do not operate MagCore® without qualified operation training.
•  Read user’s manual carefully before operation.

Handling Requirements

•  Do not use a kit after its expiration date.
•  Do not touch the reagents with bare hands. Keep away from your skin, eyes, or mucous membranes. If 

contact does occur, wash the affected area immediately with large amounts of water. If you spill the reagents, 

dilute the spill with water before wiping it up.

•  Do not allow reagents to mix with sodium hypochlorite solution or strong acids. This mixture can produce a 

highly toxic gas.

Precautions

The following procedure is designed to process maximum 16 samples at the same time. The MagCore® 

instrument can handle all numbers of samples between 1 and 16. For a detailed description of instrument setup 

and handling, refer to the MagCore® instrument Operator’s Manual.
• Store the Reagent Cartridge to +15 to +25°C before use. If you use the reagents at temperatures outside the 

recommended range, the kit may not work well. 

• Document the lot number of the kit in case of complaints or questions for RBC Bioscience Technical Service   

regarding any component of the kit (reagent cartridges or disposables). 

• Make sure you have followed the instructions regarding type and amount of sample material. Wrong 

type and amount of sample material may cause clumping of MGPs which cannot be detected by the Clot 

Detection function of the instrument. Clumping of beads may lead to low yield and purity of nucleic acids, cross-

contamination, and inhibition of downstream assays (e.g., PCR).

• After the run has finished, carefully inspect the instrument for any signs of spillage. If spillage occured, clean the 

instrument as described in the Operator’s Manual. 

• Some buffers contain guanidinium salts which are hazardous irritants. Do not allow these to come into contact 

with skin, eyes, or mucous membranes. If contact does occur, wash the affected area immediately with large 

amounts of water. If necessary, immediately contact your laboratory supervisor and seek medical assistance 

When spilling these reagents, dilute the spill with large amounts of water before attempting to clean up the spill.

• Do not allow reagents containing guanidine thiocyanate (lysis and wash buffer well ) to contact sodium 

hypochlorite (bleach) solution or acids. These mixtures produce a highly toxic gas.

• Please notice that you may be required to report serious incidents that have occurred in relation to the device to 

the manufacturer and the competent authority in which the user and/or the patient is established.

The MagCore® Nucleic Acid Extraction System is an automated nucleic acid purification system 

consisting of the MagCore® instrument, software, Kit (consumables and reagents). 

The MagCore® Nucleic Acid Extraction System is intended to be used by professional users for the 

purification of nucleic acids from biological samples for in vitro diagnostic purposes.

The MagCore® Nucleic Acid Extraction Kits are intended to be used with MagCore® Nucleic Acid 

Extraction System.

Содержание Super

Страница 1: ...UserInterface 10 EmergencyStop 10 StartPrograms 11 Iftheoptictestresultis 12 overdetectionlimit 12 Stop 14 Enablethebarcodefunction 14 Barcodescanningandediting 15 Optictestdata 15 Easymaintenance 16...

Страница 2: ...of the type of power supply at your lab consultthesellerorlocalpowercompany Forproductsintendedtooperatefrom batteryorothersources refertotheoperatinginstructions 11 Grounding or Polarization This pro...

Страница 3: ...edbytheClot Detectionfunctionoftheinstrument Clumpingofbeadsmayleadtolowyieldandpurityofnucleicacids cross contamination andinhibitionofdownstreamassays e g PCR Aftertherunhasfinished carefullyinspect...

Страница 4: ...oesnotwarrantthatsamplestreatedwithLysisBufferarecompletelyinactivatedand noninfectious Aftersampleprocessingiscompleted removeandautoclavealldisposableplastics Donoteat drinkorsmokeinthelaboratorywor...

Страница 5: ...ts Warning electricity Instructionmanualmustbereadbeforeoperating Consultinstructionsforuse Alternatecurrentinput Use byDate Nouseperiod Temperaturestorageconditions15 C 30 C Cataloguenumber productco...

Страница 6: ...0xH770 mm W27 95xD29 92xH30 31 inches NetWeight 76 5kg 168 68LB MagCoreSuper 68 5kg 151LB MagCoreHF16Plus Specification Operating Parameters Operating Environment Applications Whole Blood DNA 200 l 40...

Страница 7: ...vetteSet 10pcs X1 11 WasteBoxX1 12 BarcodeScannerX1 MagCoreSuperOnly Please refer to the machine size shown in the above figure to prepare an appropriate position for the machine and reservespaceforth...

Страница 8: ...alde16slots n mero1 16daesquerdaparaa direita 12345678910111213141516 Printer MagCoreSuperOnly TouchPanel FrontDoor TopServiceLid CoolingFans BackServiceLid OperationArea USBPort ScannerPort BarcodeSc...

Страница 9: ...etoputitintothewellifthe directionisnotcorrect 2 Putthe200 lSPtipintotheW4oftheT Rack Pleaseinsertthefrontendofthecartridgeintothespace belowthefixingplateoftheCartridgeRack 1 Putthetipintothecorrespo...

Страница 10: ...3 Testheater PleaserefertoHeaterTestchapterfortheinformationabout theoperation Step4 Testopticmodule MagCore SuperOnly PleaserefertoOpticTestchapterfortheinformationabout theoperation Whentheopticmodu...

Страница 11: ...e The above figureshowsthe function of the operation icons Start Maintenance Barcode Optics Data Please read the security information to correctly stop the machine whenanaccidenttakesplace When an eme...

Страница 12: ...ystemwillaskyouwhetherornot todeletepreviousbarcoderecord Ifthereisno barcoderecord youwillnotbeasked MagCore Superonly HF16Plusoptional Start Maintenance Barcode Optics Data 401 ProgramCode SelectElu...

Страница 13: ...rtthe USBFlashDriveandpresstheSavebutton tosavetocurrentmeasureddata After finishingtheabovesteps pleasepressNext Step 10 7 8 9 102 ProgramCode SelectOpticMeasurementFunction Enable Disable Back Press...

Страница 14: ...disappears Ifthefilesavedlasttimeislost you canretrievethisfileaccordingtothe instructionsofoptictestdatachapter OK Next Step Back 10XDilution 1 Take away and store the products which are NO need to...

Страница 15: ...esstheAbortbuttonifyouwanttoend thetest Duringtheabortionprocess moduleswillreturnto theiroriginalpositions Pleasedonotoperatethe machineduringtheprocess Themachinehasbeenstoppedandreset please presst...

Страница 16: ...code Optics Data Barcode Cancel Scan Print Data Delete All OpticalData Display Optical Data Print Optical Data Back Display Previous Optical Data Start Optical Measurement Print Previous Optical Data...

Страница 17: ...stonTest Easymaintenance 2 1 Start Maintenance Barcode Optics Data Stop O Ring Next Step Syringe O Rings 1 2 3 4 Maintenance Reject Tip Piston Test UV Heater Test Replace O Ring Motor Test Next Back M...

Страница 18: ...Well3ofT Rack 2 Pleaseadd1mlwatertotheSampleTubeandputitin theWell1oftheT Rack 3 PleaseselecttheTestW3Tip 4 Pleasecheckwhethertheliquidlevelsinalltipsare consistentwitheachother Iftheliquidlevelsareno...

Страница 19: ...ips are still on the pistons you have to press Reject Tip to remove thetipsfromthepistons PleaseselecttheRejectTipbutton Clean Piercing Needles 2 1 1 Stop PiercingNeedles Next Step Prev Maintenance Up...

Страница 20: ...ptheD2lamp Thescreenwillshowthemeasuredvaluesafter thetestisfinished YoucaninserttheUSBFlash DriveandthenpresstheSavebuttontostorethe currentdataaftertheUSBiconshowsinthestatus bar PleasetakeouttheUSB...

Страница 21: ...edles System Status Optic Test Alarm History Back Clear Save to USB AlarmMessage Back Date Time ErrorMessages Code AlarmMessage Back 0000001 ErrorCode Pleaserefertousermanualor contactyourlocalenginee...

Страница 22: ...methatyouchangedin Current Time afterthechangeisfinished System Status Prev Maintenance Update Program Vender Piercing Needles System Status Optic Test Alarm History Back SystemStatus Back System Time...

Страница 23: ...sfinished pleasepressOKtocheck whethertheUIversioniscorrect Pleasedumpthewastewhentheprogramis completed andwashthewasteboxeverytime Warning Pleaseconfirmthenameof UIversion Iftheversionisnot correct...

Страница 24: ...following figure and thenclosethecoveroftheprinter If the position of the thermal paper roll is not correct the red yellow lamp will blink Please press the Feed button to confirm the installation is...

Страница 25: ...pdated the following sections General Considerations Document Revision History Update to comply with the requirements of the IVD Regulation EU 2017 746 June 2023 EN MagCore Super HF16 Plus Operation M...

Страница 26: ...15F No 15 QiaoheRd ZhongheDist NewTaipeiCity235029 Taiwan TEL 886289121200FAX 86289121300...

Отзывы: