For further information, see the ET250 Help Cen-

ter: " ET250 >> 

 (main menu) >> Help Center".

1. Use the power supply unit provided to supply the

ET250 with power.

2. Switch on the ET250 by pressing the power key.
3. Select a language.
4. Read and follow the instructions on screen.

After the initial commissioning, an initial update

must be performed. An internet connection is re-

quired for the update.

---Separator---

4.2 Setting up a printer

To use the ET250 to print, the ET250 must be in

the same computer network as the printer.

Set up the printer according to the instructions of the

ET250 Help Center.

For further information, see the ET250 Help Cen-

ter: " ET250 >> 

 (main menu) >> Help Center".

---Separator---

4.3 Licensing the software

An internet connection is required for the licens-

ing process.

1. You can find the customer number and password in

the welcoming e-mail that follows conclusion of the

agreement.

2. Enter customer number and password.
3. Use <

Continue> to confirm your input.

The licensing process is now complete.

Should the customer number and/or password

be lost, "

 (main menu) >> Settings >> Licens-

ing >> Forgot login information?" can be used to

have the login information sent to the email ad-

dress specified during the ordering process of

the ET250.

---Separator---

5. Operation

5.1 Switching on the ET250

To prevent the formation of condensation, do not

switch on the ET250 until the ET250 has adjusted

to the ambient temperature.

Switch on the ET250 by pressing the power key.

---Separator---

5.2 Activating power-saving mode

Press power key briefly.

The ET250 will enter standby mode (power-saving

mode). If power-saving mode is already active, it

will be deactivated.

For further information, see the ET250 Help Cen-

ter: " ET250 >> 

 (main menu) >> Help Center".

---Separator---

5.3 Switching off the ET250

1. Press the power key for approx. 2 seconds, and re-

lease it when the selection menu is opened.

2. Select <Switch off>.

The ET250 will be switched off.

---Separator---

5.4 Forced shutdown

Hold the power key pressed for at least 10 seconds.

The ET250 will be switched off.

A forced shutdown may result in the loss of input

data.

Use this mode only if a shutdown of the operat-

ing system is not possible, e.g. if the touchscreen

is not responsive (frozen touchscreen) or the

screen remains black.

---Separator---

5.5 Preparing for control unit diagnosis

Use the ET250 with the OBD connection cable inclu-

ded in the scope of delivery only.

If an incorrect OBD connection cable is used, it

may result in malfunctions during control unit di-

agnosis or even damage or destroy vehicle com-

ponents.

The diagnostic connector of the vehicle must be

protected by a fuse with a max. rating of 6 A /

32 V.

Connect ET250 to vehicle via OBD connection cable

1 684 465 756.

For further information on connection options

and pin assignments, see " ET250 >> Diagnostic

connector".

---Separator---

5.5.1 Searching for vehicle systems

1. Secure the vehicle from rolling off during testing.

— Automatic transmission in park position.
— Manual transmission in neutral position and park-

ing brake engaged or wheels blocked using wheel

chocks.

2. Use the ET250 to start the vehicle system search.

For further information, see the ET250 Help Cen-

ter: " ET250 >> 

 (main menu) >> Help Center".

---Separator---

en | 8 | ET250 | Operation

Содержание ET250

Страница 1: ...Diagnostic device ET250 en Original operating instructions Diagnostic device ...

Страница 2: ...6 3 3 Scope of delivery 6 3 4 ET250 overview 6 3 5 Symbols on the rating plate 6 3 6 Functional description 7 3 6 1 Interfaces 7 3 6 2 Network port 7 3 6 3 Storage battery 7 3 6 4 Operating system 7 3 6 5 Status LED 7 4 Initial Operation 7 4 1 Setting up the ET250 7 4 2 Setting up a printer 8 4 3 Licensing the software 8 5 Operation 8 5 1 Switching on the ET250 8 5 2 Activating power saving mode 8...

Страница 3: ...sts of your own safety and will ulti mately help avoid damage to the device When a Bosch product is handed over to another person not only the operating instructions but also the safety instructions and information on its designated use must be handed over to the person Separator 1 5 Warranty and Liability By using the product you agree to the following regula tions Copyright Software and data are...

Страница 4: ... that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ig nition Never open the enclosures Separator 1 6 1 2 High voltages in hybrid vehicles and electric vehicles as well as their high voltagecomponents WARNING If high voltage components or high voltage wires are inexpertly handled there is a risk of fatal ...

Страница 5: ...wn first thendisconnect the plug of the fan motor Separator 1 6 4 Danger of burning WARNING When working on a hot engine there is a risk of injury from burning if such components as the exhaust gas manifold the turbocharger the Lambda sensor etc are touched or if parts of the body come too close to them These com ponents may be heated to temperatures of sev eral hundred degrees Celsius Depending o...

Страница 6: ...50 is a battery powered diagnostic device for workshops that can be used for control unit diagnosis It is prohibited to pass it on to end consumers Separator 3 2 Foreseeable misuse Misuse with corresponding intended use The ET250 is passed on to end consumers The ET250 may only be operated by trained work shop personnel Separator The ET250 is operated by the driver of a vehicle while driving The E...

Страница 7: ...attery The storage battery is permanently integrated into the housing and cannot be changed from the outside The fully charged storage battery of the ET250 is de signed to guarantee approx 2 hours of independent op eration The ET250 can be operated with the following voltage supply Storage battery Power supply unit OBD connection cable With the OBD connection cable plugged in the ET250 is supplied...

Страница 8: ...ower saving mode Press power key briefly The ET250 will enter standby mode power saving mode If power saving mode is already active it will be deactivated For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 3 Switching off the ET250 1 Press the power key for approx 2 seconds and re lease it when the selection menu is opened 2 Select Switch off The ET250 will ...

Страница 9: ...f the ET250 is to be sold reset the ET250 to factory settings This deletes all data and settings from the ET250 e g license information log files user settings test protocols images Restore the system by following the instructions from the ET250 Help Center For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 8 Opening the Help Center For further information s...

Страница 10: ...ion 7 2 V 2600 mAh typ Dimensions W x H x D 295 x 180 x 40 mm Weight with battery without power sup ply unit 1 2 kg Degree of protection IP 20 Maximum operating altitude with power supply unit 2000 m Maximum operating altitude without power supply unit 4000 m Voltage supply from the vehicle via OBD 10 V 28 V Voltage supply from the vehicle via OBD 1 6 A Operating Temperature 0 C 40 C 32 F 104 F St...

Страница 11: ...1 689 989 380 2018 08 01 Robert Bosch GmbH ET250 11 en ...

Страница 12: ...1 689 989 380 2018 08 01 Robert Bosch GmbH LastPage ET250 11 en Robert Bosch GmbH Franz Oechsle Str 4 73207 Plochingen Deutschland www bosch com bosch prueftechnik bosch com 1 689 989 380 2018 08 01 ...

Отзывы: