MAG TOOLS ET250 Скачать руководство пользователя страница 7

1 689 989 380 | 2018-08-01

Robert Bosch GmbH

US declaration of conformity

---Separator---

The ET250 may only be used by trained and

instructed workshop personnel. The ET250 is

not suitable for installation and use by end

consumers as improper installation or use

may lead to the vehicle behaving incorrectly

while driving and cause severe injury or

death.

---Separator---

Certification for Ukraine

---Separator---

Certification for the Russian Federation

---Separator---

Certification for Australia

---Separator---

Li-ion

Recycling of the portable battery for Japan

---Separator---

3.6 Functional description

The OBD connection cable is used to connect the

ET250 to the vehicle. Operation is by hand using the

TFT touchscreen and the on-screen keyboard. While the

device is connected to the vehicle by OBD interface, it

is possible to perform a control unit diagnosis and to

read the OBD fault memory of the vehicle. An external

printer (optional accessory) connected by WLAN can be

used to print the data and measured values. The ET250

and the accessories are supplied in a protective case.

---Separator---

3.6.1 Interfaces

DIAG

A

A

B

1

5

V

2

4

5 6 7 8

3

1

 

2:

 

View of ET250 interfaces

(1) Recovery key

(2) Power supply port (15 V DC)

(3) Status LED

(4) OBD connection cable port

(5) Network port (LAN 10/100 Mbit)

(6) USB 2.0 A port (1x)

(7) WLAN USB adapter (WLAN 802.11 b/g/n)

(8) USB 2.0 B port (1x)

---Separator---

3.6.2 Network port

The network port serves to provide a stable internet

connection in locations where a WLAN connection can-

not be reliably maintained due to interference.

The network port can be used during initial com-

missioning and for software updates.

---Separator---

3.6.3 Storage battery

The storage battery is permanently integrated into the

housing and cannot be changed from the outside.
The fully charged storage battery of the ET250 is de-

signed to guarantee approx. 2 hours of independent op-

eration.
The ET250 can be operated with the following voltage

supply:

• Storage battery
• Power supply unit
• OBD connection cable

With the OBD connection cable plugged in, the

ET250 is supplied with power by the vehicle and

recharged.

Charge the storage battery for at least 2 hours

before using the ET250 in battery mode.

---Separator---

3.6.4 Operating system

The ET250 runs a closed operating system developed

on the basis of AOSP (Android Open Source Project). It

is not possible to install third-party software or apps

(e.g. from the Google Play Store).

---Separator---

3.6.5 Status LED

The status LED on the back of the housing indicates

various statuses of the ET250:

LED off

ET250 not switched on.
LED flashes green 1 time per second

Normal operation. ET250 starting or already active (al-

so in power-saving mode).
LED flashes green every 5 seconds

ET250 is switched off and being charged.
LED flashes yellow 1 time per second

Internal communication failure. 

Ausschalten erzwingen 

 

8

 

"Forced shutdown"

 

.

LED flashes red 1 time per second

ET250 switched on and supplied with power, but the

system does not start (Recovery Mode).

---Separator---

4. Initial Operation

4.1 Setting up the ET250

Before initial commissioning, make sure the volt-

age supply matches the voltage rating of the pow-

er supply unit provided.

The ET250 supports WLAN frequencies in the 2.4-

GHz range of channels 1 (2412 MHz) to 11

(2462 MHz). WLAN computer networks outside

the frequency range are not displayed.

The WLAN configuration always depends on the

configuration of the router / access point availa-

ble.

The "Extended Range" function is not supported.

Initial Operation | ET250 | 7 | en

Содержание ET250

Страница 1: ...Diagnostic device ET250 en Original operating instructions Diagnostic device ...

Страница 2: ...6 3 3 Scope of delivery 6 3 4 ET250 overview 6 3 5 Symbols on the rating plate 6 3 6 Functional description 7 3 6 1 Interfaces 7 3 6 2 Network port 7 3 6 3 Storage battery 7 3 6 4 Operating system 7 3 6 5 Status LED 7 4 Initial Operation 7 4 1 Setting up the ET250 7 4 2 Setting up a printer 8 4 3 Licensing the software 8 5 Operation 8 5 1 Switching on the ET250 8 5 2 Activating power saving mode 8...

Страница 3: ...sts of your own safety and will ulti mately help avoid damage to the device When a Bosch product is handed over to another person not only the operating instructions but also the safety instructions and information on its designated use must be handed over to the person Separator 1 5 Warranty and Liability By using the product you agree to the following regula tions Copyright Software and data are...

Страница 4: ... that all test connections are properly plugged in and secure Before disconnecting the B cable from the engine ground or battery B switch off the ig nition Never open the enclosures Separator 1 6 1 2 High voltages in hybrid vehicles and electric vehicles as well as their high voltagecomponents WARNING If high voltage components or high voltage wires are inexpertly handled there is a risk of fatal ...

Страница 5: ...wn first thendisconnect the plug of the fan motor Separator 1 6 4 Danger of burning WARNING When working on a hot engine there is a risk of injury from burning if such components as the exhaust gas manifold the turbocharger the Lambda sensor etc are touched or if parts of the body come too close to them These com ponents may be heated to temperatures of sev eral hundred degrees Celsius Depending o...

Страница 6: ...50 is a battery powered diagnostic device for workshops that can be used for control unit diagnosis It is prohibited to pass it on to end consumers Separator 3 2 Foreseeable misuse Misuse with corresponding intended use The ET250 is passed on to end consumers The ET250 may only be operated by trained work shop personnel Separator The ET250 is operated by the driver of a vehicle while driving The E...

Страница 7: ...attery The storage battery is permanently integrated into the housing and cannot be changed from the outside The fully charged storage battery of the ET250 is de signed to guarantee approx 2 hours of independent op eration The ET250 can be operated with the following voltage supply Storage battery Power supply unit OBD connection cable With the OBD connection cable plugged in the ET250 is supplied...

Страница 8: ...ower saving mode Press power key briefly The ET250 will enter standby mode power saving mode If power saving mode is already active it will be deactivated For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 3 Switching off the ET250 1 Press the power key for approx 2 seconds and re lease it when the selection menu is opened 2 Select Switch off The ET250 will ...

Страница 9: ...f the ET250 is to be sold reset the ET250 to factory settings This deletes all data and settings from the ET250 e g license information log files user settings test protocols images Restore the system by following the instructions from the ET250 Help Center For further information see the ET250 Help Cen ter ET250 main menu Help Center Separator 5 8 Opening the Help Center For further information s...

Страница 10: ...ion 7 2 V 2600 mAh typ Dimensions W x H x D 295 x 180 x 40 mm Weight with battery without power sup ply unit 1 2 kg Degree of protection IP 20 Maximum operating altitude with power supply unit 2000 m Maximum operating altitude without power supply unit 4000 m Voltage supply from the vehicle via OBD 10 V 28 V Voltage supply from the vehicle via OBD 1 6 A Operating Temperature 0 C 40 C 32 F 104 F St...

Страница 11: ...1 689 989 380 2018 08 01 Robert Bosch GmbH ET250 11 en ...

Страница 12: ...1 689 989 380 2018 08 01 Robert Bosch GmbH LastPage ET250 11 en Robert Bosch GmbH Franz Oechsle Str 4 73207 Plochingen Deutschland www bosch com bosch prueftechnik bosch com 1 689 989 380 2018 08 01 ...