5.3.1. Mains connection.
Fly Series systems are supplied with CN-0010 PowerCon-E/F CEE 7/7 mains cable (part number 00-
00005561). Use only original or supplied by manufacturer mains cables!.
Fly Series systems are equipped with PowerCon B mains power outlets for mains link to additional Fly
system. For linking several Fly 6 / Fly 6L full-range systems CN-0011 PowerCon link cable may be used.
(Part number 00-00005562, not supplied with the system).
Fly Series systems nominal mains power specifications: AC 220V, 50/60 Hz.
Nominal voltage tolerance: 100 - 250 V.
To power the system up, connect the mains cable to the system, then to the power outlet.
To completely power down the system, disconnect the mains cable from the power outlet.
5.3.2. Maximum number of Fly Series systems for power linking.
Do not exceed the number of power linked system listed below:
Fly 6 - no more than 5 pcs.
Fly 6L - no more than 5 pcs.
Fly Sub 12 - no more than 4 pcs.
Fly Sub 12L - no more than 4 pcs.
Fly Sub 15 - no more than 2 pcs.
Fly Sub 18 - no more than 2 pcs.