-16-
5.3
Storage
If the machine is out of service for a lengthy period of
time, it should be thoroughly cleaned (see chapter
5.1). Spray bright metal panels with a rustproofing
agent.
Store the machine only in dry rooms, where it is pro-
tected against weathering.
6
Troubleshooting
Some of the most frequent defects and their causes are listed in the following chart. In case of other defects,
contact your dealer or the MAFELL customer service.
7
Optional accessories
Stop plate, cpl.
Ref. No. 039 156
Special drill mount
Ref. No. 039 160
Supplementary handle, cpl.
Ref. No. 039 203
Ejector drift 1 DIN 317
Ref. No. 093 001
8
Exploded drawing and spare parts list
The corresponding information in respect of spare parts can be found on our homepage: www.mafell.com
The determination of the causes of existing defects and their elimination always require
increased attention and caution. Pull out the mains plug beforehand!
Defect
Cause
Elimination
Machine cannot be switched on
No mains voltage
Check power supply
Carbon brushes worn
Take the machine to a MAFELL cus-
tomer service shop
Machine stops while drilling is in pro-
gress
Mains failure
Check mains back-up fuse
Drill bit jams
Blunt bit
Replace the drill bit or resharpen it