5.2

 

Hints and information 

When vacuuming dry materials, the folded filter  5 

(fig. 2) must be completely dry. 

During wet vacuuming, the built-in sensor prevents 
the  maximum  filling  level  in  the  container  from 
being  exceeded.  The  device  no  longer  vacuums 
when the container is full. Switch off motor. Pull the 

dust extractor plug and empty the container. 

If  the  sensor  responds  when  vacuuming  larger 
amounts of liquid (more than one container filling), 

switch off the device and empty the container. 

If  the  volume  flow  display  3  (fig.  1)  lights  up  on 

restart, this may have the following reasons: 

-

 

Container, filter bag 8 (fig. 4) full. 

-

 

Extraction hose clogged. 

-

 

Air cross sections of the dust generator too 

small. 

  

On  completion  of  work,  but  especially  if  you  do  not 
intend  to  use  the  device  for  a  longer  period  of  time, 

you should: 

  

Discharge any dirt and liquids. 

Store  the  extraction  hose  such  that  there  are  no 

kinks. 

Neatly  reel  up  the  mains  cable  and  protect  it 

against damage. 

  

6

 

Service and maintenance 

 

Danger 
Pull the power plug during all 

service work. 

  

 

After longer periods of operation, 
MAFELL recommends to take the 
device to an authorised MAFELL 
customer service shop for 

inspection. 

  

The storage place must be dry and frost-protected. 
If the  device fails despite diligent manufacturing and 
test procedures, the repair must be carried out by an 
authorised  customer  service  station  for  MAFELL 

products. 

  

 

Danger 
Only use MAFELL accessories and 
spare parts. Have components, the 
replacement of which has not been 
described in this document, 
replaced at a MAFELL customer 

service station. 

  

6.1

 

Maintenance 

For  maintenance  by  the  user,  the  device  must  be 
disassembled, cleaned and serviced as far as this is 
feasible  without  causing  any  danger  for  the 

maintenance personnel and other persons.  
Suitable  precautions  include  cleaning  before 
disassembly,  providing  for  locally  filtered  forced 
venting  at  the  place  where  the  device  is 
disassembled,  cleaning  the  maintenance  area  and 

suitable personal protective clothing. 
On  machines  class  M,  the  outside  of  the  machine 
should  be  cleaned  by  means  of  dust  extraction 
methods  and  wiped  clean  or  should  be  treated  with 
sealant before they are removed from the hazardous 
area. 
All machine parts must be considered contaminated if 
they  are  removed  from  the  hazardous  area  and 
suitable action must be taken to avoid the dust from 

being dispersed. 
Such objects must be disposed of in impervious bags 
in  compliance  with  the  valid  regulations  for  the 

disposal of such waste. 

Содержание S 35 M

Страница 1: ...le Sicherheitshinweise und Anweisungen f r die Zukunft auf WARNING Please read all safety instructions and directions Failure to comply with the safety instructions and directions can cause electric s...

Страница 2: ...edshenvisninger og instruktioner En manglende overholdelse af sikkerhedshenvisningerne og instruktionerne kan f re til elektrisk st d brand og eller alvorlige kv stelser Opbevar alle sikkerhedshenvisn...

Страница 3: ...3...

Страница 4: ......

Страница 5: ...2 9 Residual risks 19 3 Safety instructions 19 4 Setting Adjustment 21 4 1 Assembly 21 4 2 Mains connection 21 4 3 Changing the folded filter cartridge 21 4 4 Changing the filter bags 21 4 5 Disposal...

Страница 6: ...e on the rating plate attached to the motor casing CE symbol to document compliance with the basic safety and health requirements according to Appendix I of the Machinery Directive For EU countries on...

Страница 7: ...ir test site at a distance of 1 5 m from the device surface 2 5 Scope of supply Dust extractor S 35 M complete with 2 folded filter cartridges polyester nano coated 1 PE discharge disposal bag 25 35l...

Страница 8: ...peration outdoors in the rain or in rooms with potentially explosive atmospheres The dust extractor S 35 M may only be used set up and serviced by persons who are acquainted with the device and have b...

Страница 9: ...plug by its cable out of the socket outlet Pull out the power plug prior to cleaning or emptying and prior to eliminating any malfunctions Pay attention that the cable is protected against oil and hea...

Страница 10: ...ed next to the motor protection filter 6 fig 2 If they are heavily soiled rinse out and reinsert in dry condition Damaged motor protection filters must be replaced 4 4 Changing the filter bags Danger...

Страница 11: ...M and HEPA with special container and rotary valve in the intake port of types S 35 M and S 35 HEPA are suitable for use with PE discharge and disposal bags Operation of the rotary valve Set the red r...

Страница 12: ...extractor S 35 M is equipped with an electric suction force regulator The turning knob 2 can be used to adapt the suction power to the material to be vacuumed Put power plug of the dust extractor int...

Страница 13: ...service shop for inspection The storage place must be dry and frost protected If the device fails despite diligent manufacturing and test procedures the repair must be carried out by an authorised cu...

Страница 14: ...ese always requires increased attention and caution Pull the mains plug beforehand Some of the most frequent defects and their causes are listed in the following chart In case of other defects contact...

Страница 15: ...pair pleated filter cartridge polyester fleece Order No 093674 4 m extraction hose LW27 machine connection 35 mm antistatic Order No 093684 5 m extraction hose LW35 machine connection 35 mm antistatic...