–
enb:
•
0: disable trigger
•
1: specify timeout
–
trigger_type:
•
0: unused
•
1: high-to-low transition trigger
•
2: low-to-high transition trigger
•
3: unused
exec :
AT#DITRIGENB=1,0,1
OK
state :
AT#DITRIGENB?
#DITRIGENB:1,0,1
#DITRIGENB:2,1,3
OK
info :
AT#DITRIGENB=?
#DITRIGENB:(1-2),(0-1),(0-3)
OK
10.3
AT#MSGPER
Configure Message ID and message strings associated with the 2 pins
ALLOWED: exec-state-info
AT##MSGPER=(pin_number),(interval),(count)
–
pin_number: 1-2
–
interval: how often messages are generated, in sec. Value 0-60000
–
count: number of messages generated. Value 0-100
exec :
AT#MSGPER=2,10,3
OK
state :
AT#MSGPER?
#MSGPER: 1,0,0
#MSGPER: 2,10,3
OK
44
Confidential, the whole document is the sole property of Maestro Wireless Solutions Ltd.
Please contact us on
support.maestro-wireless.com