background image

 

SU-200B  

Installation Manual 

(For Technicians Only) 

 

 

 

 

 

 

 

PLC Slave Unit 

 

 

 

Plug into the future 

Powerline Communication by Xeline 

 

 

 
 

Xeline Co., Ltd. 

Содержание SU-200B

Страница 1: ...SU 200B Installation Manual For Technicians Only PLC Slave Unit Plug into the future Powerline Communication by Xeline Xeline Co Ltd...

Страница 2: ...terference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on th...

Страница 3: ...2 3 Safety Precautions 7 3 Getting to Know the SU 200B 8 3 1 Front View 8 3 2 Rear View 8 3 3 Product Specifications 9 3 4 Minimal Requirements for the Subscriber s PC 9 4 Installing the SU 200B 10 4...

Страница 4: ...Figure 6 Connecting the Power Cable 10 Figure 7 Connecting the SU 200B to the Subscriber s PC 11 Figure 8 Network and Dial up Connections 12 Figure 9 Local Area Connection Properties 12 Figure 10 Int...

Страница 5: ...er to instantly access the Internet or home network from any electrical outlet in the home or office One SU 200B is needed for each PC or device that you wish to connect to the network Due to the smoo...

Страница 6: ...manufactured by E Tech Electronics Co Ltd E Tech Electronics Co Ltd Model No cu1330b Model No cu1330b Figure 2 SU 200B Package Contents If there is a missing item or any visible damage notify your se...

Страница 7: ...r bathtubs Areas where sudden changes in temperature occur Under direct sunlight 4 Do not use this equipment near heaters or other devices that emit high heat 5 Do not place heavy objects on top of th...

Страница 8: ...ed SYNC LINK Blinks when the detected PLC signals are valid LAN Activates when the SU 200B LAN port is connected to the PC Blinks during data transmission between the SU 200B and the PC 3 2 Rear View...

Страница 9: ...ks Data rates Up to 24Mbps Interface RJ 45 For connection with NIC Dimensions 186 X 143 X 40mm W x D x H Power AC110 240V 50 60Hz 3 4 Minimal Requirements for the Subscriber s PC CPU Intel Pentium 166...

Страница 10: ...SU 200B 4 1 Connecting the SU 200B to the Subscriber s PC Insert the RJ 45 cable into the RJ 45 Ethernet port of the SU 200B Figure 5 Connecting the RJ 45 cable and SU 200B Insert the power cable into...

Страница 11: ...the SU 200B and check if the LAN LED is activated The SU 200B is remotely configured by the EU 200B through automatic process Therefore there is no need to manually configure the SU 200B1 Wait approx...

Страница 12: ...fessional operating system Configuration procedures may differ according to the subscriber PC O S Click the START button in your taskbar and go to NETWORK AND DIAL UP CONNECTIONS Go to START SETTINGS...

Страница 13: ...vided by the Internet Service Provider ISP i For DHCP IP Addresses Select OBTAIN AN IP ADDRESS AUTOMATICALLY Then select the OBTAIN THE FOLLOWING DNS SERVER ADDRESS option Click OK to continue ii For...

Страница 14: ...SHOW ICON IN TASKBAR WHEN CONNECTED option and click OK Click Figure 12 Show Icon in TaskBar Configuring your computer for Internet connection is now complete You can check your connection status by...

Страница 15: ...notice 15 4 3 Final Check Ping Test Perform the following procedures in order to check if the installation is successful Run Command window Go to START RUN CMD Figure 14 Command Prompt Window Type ip...

Страница 16: ...Check Any Gateway DNS Servers Check Any DNS Servers In case of Fixed IP Physical Address XX XX XX XX XX XX Check Dhcp Enabled No IP Address Check Configured IP Subnet Mask Check Configured Subnet Mask...

Страница 17: ...e SU 200B in order to reset the configuration into factory default mode Turn off the power of the SU 200B Disconnect the RJ 45 cable Use a long sharp instrument such as a tweezers in order to push dow...

Страница 18: ...B and the NIC of the PC Check if the NIC connection is disabled in the Local Area Network window Pinging to the default Gateway IP is unsuccessful Check for typos in the ping command Check if the Gate...

Страница 19: ...ctive owners z Information in this document is subject to change without notice No part of this document may be reproduced or transmitted in any form or by any means electronical or mechanical for any...