Connection Diagram Examples
You can connect your input equipment, MADRIX
®
ORION, supply of power, and
data cables in different ways. The following pages show several examples. These
schemes are to be seen independently of the direction, position, and mounting
method. Please see page 6 and page 7 for further information.
SUPPLY POWER TO ORION ONLY ONCE! DO NOT CONNECT V+
MULTIPLE TIMES BY CONNECTING IT VIA PORT 1/2 AND POWER.
Legend
Connection required for GROUND.
Connection required for DATA.
Connection required for V+.
Example A
Description:
Power is supplied only once to ORION and also used for the input equipment. Each
Port is protected with 500 mA max. For example, a potentiometer is connected to Port 1 via
GROUND, DATA at Pin1, and V+, while a switch is connected to Port 2 via DATA at Pin 5 and V+.
Daisy-Chain Support
MADRIX
®
ORION features 2 separate Ethernet network ports. Either one is
fully functionally for IN and OUT and can be used for the data connection without
using a separate network switch or router. It is recommended to connect a
maximum of 8 units after one another in a row.