11

  EN

Web Configuration Through A Web Browser

Step 1)  Connect MADRIX

®

 ORION and your computer to the same network.

Step 2)  Assign correct network settings in the Windows operating system. 
 

(Recommended: IP address 10.0.0.1 / Subnet mask 255.0.0.0)

Step 3)   Open your web browser and enter the IP address of MADRIX

®

 ORION. 

 

(You can find the default IP address on the side of the ORION device.)

Step 4)  The built-in web configuration page will be launched. Confirm or  
 

change the IP address, Pin Input, DMX Channels, and Network 

 

Output. The device then sends out data over network as configured.

Step 5)   Change any other settings as required. Apply changes with ‘Set’.

MADRIX Device Configuration In The MADRIX

®

 Software

Step 1)  Connect MADRIX

®

 ORION to your computer via USB or via Ethernet.

Step 2a) For the USB connection, Microsoft

®

 Windows

®

 will install the  

 

interface drivers automatically. When ready, the status LED for  

 

USB will fade between red and green; as described on page 12. Start  

 

the MADRIX

®

 Software and enable USB drivers. Go to ‘Preferences’  

 

> ‘Options…’ > tab ‘Devices USB’. Activate ‘MADRIX ORION’ and  

 

click ‘OK’. (The driver is activated by default.)

Step 2b) For the Ethernet connection, enable network drivers in MADRIX

®

 

Go to ‘Preferences’ > ‘Options…’ > tab ‘Devices Network’. 

 

Activate ‘inoage - MADRIX’ and click ‘OK’. (The driver is activated  

 

by default.)

Step 3)  In MADRIX

®

, go to ‘Tools...’ > ‘MADRIX Device Configuration...’. A  

 

new window will open. Click on the search button (loupe 

 

 

icon) and it will search for connected devices. Select your device in  

 

the list and click on the configuration button (gear wheel icon).

Step 4)  Confirm or change the IP address, Pin Input, DMX Channels, and  
 

Network Output and any other settings as required. Apply changes  

 

with ‘Set’. The device then sends out data over network as configured.

3)

 

Device Configuration

You can access and change specific device settings, including the IP address, Pin 
Input, DMX Channels, and Network Output, in different ways.

Please note:

 In order to put MADRIX

®

 ORION fully into operation, please 

configure the device according to your requirements and input equipment.

Содержание ORION

Страница 1: ...ORION Quick Start Guide T echnical Manual...

Страница 2: ...ou fully understand all information This MADRIX ORION Quick Start Guide is written in English and German Diese Kurzanleitung wurde in englischer und deutscher Sprache verfasst Developed and made in Ge...

Страница 3: ...actions that inoage GmbH does not have influence on no matter if the damages as well as consequential damages are direct or indirect whether they are special damages or others nor if the damage is cau...

Страница 4: ...ny other liquids Turn off the power if you are not using the device for a long time Avoid unwanted voltage on the cables at all times Do not remove any parts from the unit or connect to an ungrounded...

Страница 5: ...he same time Technical Specifications Supply of power See pages 6 9 Power supply As provided external Power consumption Input signals Ports Input pins Ethernet USB port Case Dimensions Weight Temperat...

Страница 6: ...e the MADRIX Software in order to access all features of MADRIX ORION including the USB connection which requires MADRIX 5 Support for Art Net Streaming ACN is already available with previous versions...

Страница 7: ...port incl 2 status LEDs 4 USB port 5 Status LED for Power 6 Status LED for USB 7 Status LED for Port 1 8 Status LED for Port 2 9 Port 1 10 Reset button 11 DIN rail unlocking clip 12 Port 2 2x Mounting...

Страница 8: ...vely use the provided external power supply Make sure to switch to 5 V yellow arrow on the power adapter itself by using a suitable tool up to 12 V or when using your own power supply up to 24 V You c...

Страница 9: ...required for GROUND Connection required for DATA Connection required for V Example A Description Power is supplied only once to ORION and also used for the input equipment Each Port is protected with...

Страница 10: ...lus a 1k 10k resistor Example C Description Power is supplied to ORION and supplied separately to the input equipment The sensor is connected to Port 1 via GROUND and DATA at Pin 1 but not V Example D...

Страница 11: ...art the MADRIX Software Step 3 In the MADRIX Software go to Tools MADRIX Device Configuration A new window will open Click on the search button loupe icon and the software will search for connected de...

Страница 12: ...een as described on page 12 Start the MADRIX Software and enable USB drivers Go to Preferences Options tab Devices USB Activate MADRIX ORION and click OK The driver is activated by default Step 2b For...

Страница 13: ...f No data is sent No data is sent Blinking green Receiving data changes The input port works Receiving data changes The input port works STATUS STATUS LEDS ETHERNET PORTS Green off 10 MBit s connected...

Страница 14: ...rail Using The MADRIX Software You can mainly use 3 operating modes together with the MADRIX Software DMX IN Via Art Net DMX IN Via Streaming ACN DMX IN Via USB In the MADRIX Software make sure to ac...

Страница 15: ...formity The device complies with the requirements set forth in the council Directive of the law of the Member States relating to electromagnetic compatibility 2014 30 EU the Low Voltage Directive 2014...

Страница 16: ...g ACN is recommended for large projects by connecting multiple devices to a switch 1 GBit s via suitable components to create a network or use the built in daisy chain support see page 8 Where can I f...

Страница 17: ...onen verstanden haben Diese Kurzanleitung wurde in englischer und deutscher Sprache verfasst This MADRIX ORION Quick Start Guide is written in English and German Entwickelt und hergestellt in Deutschl...

Страница 18: ...keinen Einfluss hat ganz gleich ob es sich um direkte oder indirekte Sch den Folgesch den oder spezielle Sch den handelt und ob diese vom Besitzer oder einer dritten Person verursacht wurden Eingetra...

Страница 19: ...iten Trennen Sie das Ger t bei l ngerer Nichtbenutzung von der Spannungsversorgung Entfernen Sie keine Teile vom Ger t oder andere Bauteile und verbinden Sie es niemals mit einem ungeerdeten Stromkrei...

Страница 20: ...rsorgung Siehe Seiten 6 9 Netzteil Mitgeliefert extern Stromaufnahme Eingangssignale Ports Eingangspins Netzwerk USB Anschluss Geh use Abma e Gewicht Temperaturbereich Relative Luftfeuchte 5 V 24 V Gl...

Страница 21: ...SB Verbindung welche MADRIX 5 ben tigt wird die MADRIX Software empfohlen Art Net und Streaming ACN werden bereits von vorherigen Versionen unterst tzt Min Systemanforderungen f r MADRIX und unterst t...

Страница 22: ...inks inkl 2 Status LEDs 4 USB Anschluss 5 Status LED f r Strom 6 Status LED f r USB 7 Status LED f r Anschluss 1 8 Status LED f r Anschluss 2 9 Anschluss 1 Port 1 10 Reset Taste 11 Hutschienen Entrieg...

Страница 23: ...mitgelieferte Netzteil verwendet werden Dabei muss 5 V gelber Pfeil auf dem Netzteil selber mit einem passenden Werkzeug eingestellt werden bis zu 12 V oder bei Nutzung eines eigenen Netzteils bis zu...

Страница 24: ...bindung erforderlich f r V Die Eingabeger te und ORION k nnen auf verschiedene Arten verbunden werden Auf den folgenden Seiten sind verschiedene Beispiele dargestellt Diese sind unabh ngig von der Aus...

Страница 25: ...it 1k 10k angeschlossen Beispiel C Beschreibung Die Spannungsversorgung wird f r ORION und das Eingabeger t separat bereit gestellt Der Sensor ist an Port 1 ber MASSE und DATEN an Pin 1 angeschlossen...

Страница 26: ...MADRIX ORION mit Ihrem Computer ber USB Schritt 2 Starten Sie die MADRIX Software Schritt 3 ffnen Sie in der MADRIX Software das Men Werkzeuge MADRIX Ger tekonfiguration Bet tigen Sie das Lupen Symbo...

Страница 27: ...MADRIX Software die Treiber unter Systemeinstellungen Optionen Reiter USB Ger te MADRIX ORION aktivieren Mit OK best tigen Der Treiber ist standardm ig aktiviert Schritt 2b F r die Netzwerkverbindung...

Страница 28: ...at keinen Strom Permanent gr n Spannungsversorgung liegt an Das Ger t hat Strom Gr n blinkend Bootloader aktiviert Zur cksetzen Firmware einspielen STATUS STATUS LED USB Ausgeschaltet USB nicht angesc...

Страница 29: ...Art Net Danach k nnen Ger te und Datenempfang konfiguriert und aktiviert werden Systemeinstellungen Ger teverwaltung DMX Ger te Systemeinstellungen Ger teverwaltung DMX Eingang Montage auf Hutschienen...

Страница 30: ...dhabung oder technische Probleme auftauchen konsultieren Sie bitte die weiteren Benutzerhandb cher kontaktieren Sie Ihren H ndler oder besuchen Sie die Internetseite www madrix com Anfragen k nnen auc...

Страница 31: ...treaming ACN wird f r gro e Projekte mit mehreren Ger ten empfohlen Diese ber geeignete Komponenten mit einem Switch 1 GBit s als Netzwerk verbinden oder die eingebaute Netzwerkreihenschaltung nutzen...

Страница 32: ...www madrix com...

Отзывы: