Product User Guide
Reading Rate 1 reading every second up to 1 reading every 24 hours
Memory 32,256 readings
Memory Wrap Around Yes
Start Modes Immediate Start & Delayed Start
Stop Modes
• Manual through software
• Delayed Stop
• Timed (specific date and time)
Real Time Recording The device may be used with PC to monitor and record data in real-time
Alarm
User configurable audible, on-screen, email and text (SMS) alarms.
Alarm Delay:
A cumulative alarm delay may be set in which the device
will activate the alarm (via LED) only when the device has recorded a
user specified time duration of data.
Audible Alarm
Functionality
1 beep per second for reading alarm above/below threshold
LED Functionality
• Green LED blinks every 10 seconds to indicate unit is logging
• Blue LED blinks every 30 seconds to indicate unit is in wireless mode
• Red LED blinks every 1 second to indicate alarm condition
Password Protection
An optional password may be programmed into the device to restrict access
to configuration options. Data may be read out without the password.
Engineering Units
Native measurement units can be scaled to display measurement units
of another type. This is useful when monitoring voltage outputs from
different types of sensors such as temperature, CO2, flow rate and more.
Calibration Digital Calibration through software.
Calibration Date Automatically recorded through the device
Battery Type Ultralife 9V Lithium included;
user replaceable
Battery Life Approximately 4 years typical for 15 minute reading rate
Data Format µA, mA, A
Time Accuracy ± 1 minute/month
Computer Interface
USB to mini USB, 250,000 baud for standalone operation or RFC1000/
RFC1000-CE/RFC1000-IP69K required for wireless operation
Software XP SP3/Vista/Windows 7/Windows 8 (MadgeTech 4 only)
Operating
Environment
-20 °C to +60 °C (-4 °F to +140 °F) 0 %RH to 95 %RH non-condensing
Dimensions
• 20 mA & 3 A:
3.19 in x 3.5 in x 0.95 in
(80.9 mm x 88.9 mm x 24.1 mm) -
Data logger only
• 160 mA:
3.17 in x 3.5 in x 0.95 in
(80.5 mm x 88.9 mm x 24.1 mm) -
Data logger only
Weight 4.1 oz (0.2563 lbs)
Enclosure Material ABS Plastic
Approvals US (FCC), CA (IC), CE, South Korea (KCC), China (CMIIT), Japan (LCIE)
RFCurrent2000A General Specifications
6
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, a separation distance of 20 cm or more should
be maintained between the antenna of this device and persons during operation. To ensure compliance, operation at closer than this
distance is not recommended. The antenna(s) used for this transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.