MadgeTech RFC1000 Скачать руководство пользователя страница 15

RFC1000

• “This device complies with Part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation.”

• “To satisfy FCC RF Exposure requirements for mobile and base station transmission devices, 
a separation distance of 20cm or more should be maintained between the antenna of 
this device and persons during operation. To ensure compliance, operation at closer than 
this distance is not recommended. The antenna(s) used for this transmitter must not be 
co-located or operating in conjunction with any other antenna or transmitter.”

• “This device complies with Industry Canada license-exempt RSS standard(s). Operation is 
subject to the following two conditions: (1) this device may not cause interference, and (2) 
this device must accept any interference, including interference that may cause undesired 
operation of the device.

Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils 
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1) 
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter 
tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre 
le fonctionnement.”

• “Under Industry Canada regulations, this radio transmitter may only operate using an 
antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry 
Canada. To reduce potential radio interference to other users, the antenna type and its gain 
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more 
than that necessary for successful communication. 

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut 
fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé 
pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage 
radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain 
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 
nécessaire à l’établissement d’une communication satisfaisante.”

Compliance Information

13

Содержание RFC1000

Страница 1: ...RFCurrent2000A To view the full MadgeTech product line visit our website at www madgetech com RFCurrent2000A Wireless Current Data Logger Product User Guide ...

Страница 2: ...tional Features Operation 3 Mounting Instructions 4 Product Maintenance 5 Recalibration 5 RMA Instructions 5 General Specifications 6 7 RFC1000 Transceiver Product Overview 9 Installation Guide 9 Mounting Instruction 10 Channel Programming 11 Deployment Activation 12 General Specifications 12 Compliance Information 13 Troubleshooting Tips Back Cover Table of Contents ...

Страница 3: ...e Start icon 7 To download data select the device in the list click the Stop icon and then click the Download icon A graph will automatically display the data Quick Start Steps 1 Install the MadgeTech 4 Software and USB Drivers onto a Windows PC 2 Before plugging the data logger in the computer make sure the wireless setting on the device is set to Wireless OFF If wireless mode is on press and hol...

Страница 4: ...FC1000 wireless transceiver to transmit data back to a central PC The RFCurrent2000A transmits up to 500 ft line of sight to the RFC1000 transceiver Multiple RFC1000 s can be used as repeaters and transmit up to 1000 ft line of sight to other RFC1000 s This allows the data to be sent over a greater distance Selection Buttons The logger is designed with 3 direct selection buttons Scroll Units and W...

Страница 5: ...have met before notifications occur and select which notifications will occur from the drop down menus 4 If selecting to receive notifications by email or text message click Email settings and make sure the correct info has been entered Email and text message notifications will not be received if settings are incorrect 5 Click OK The OK button will be disabled if the Rule name box is empty Changin...

Страница 6: ...ottom of the logger snaps in place to use and mount the unit on a table top or horizontal surface The base can also securely snap to the backside of the logger for wall mounting if desired as shown below There are two holes in the base to allow for screws for mounting Mounting Instructions 4 ...

Страница 7: ...the blank fields 3 Complete the applicable fields on the form including customer Billing and Shipping information even if they are the same Please see the field explanation below for a more detailed description about questions asked in the Device Information section 4 When all of the fields are complete click Generate RMA 5 Print out the confirmation page that follows containing the RMA number and...

Страница 8: ... Date Automatically recorded through the device Battery Type Ultralife 9V Lithium included user replaceable Battery Life Approximately 4 years typical for 15 minute reading rate Data Format µA mA A Time Accuracy 1 minute month Computer Interface USB to mini USB 250 000 baud for standalone operation or RFC1000 RFC1000 CE RFC1000 IP69K required for wireless operation Software XP SP3 Vista Windows 7 ...

Страница 9: ... Battery Warning WARNING BATTERY MAY LEAK FLAME OR EXPLODE IF DISASSEMBLED SHORTED CHARGED CONNECTED TOGETHER MIXED WITH USED OR OTHER BATTERIES AND OR EXPOSED TO FIRE HIGH TEMPERATURE DISCARD USED BATTERY PROMPTLY KEEP OUT OF REACH OF CHILDREN Specifications subject to change See MadgeTech s terms and conditions at www madgetech com 7 Sensor Type Current Sensing Circuitry Nominal Range 20 mA 160 ...

Страница 10: ...Product User Guide RFC1000 Wireless Transceiver 8 Other models available RFC1000 CE Approved for European markets RFC1000 IP69K Splash Proof for harsh environments ...

Страница 11: ... condensing The RFC1000 is rated IP40 and is protected against solids that are greater than 1mm in size This device is not water resistant LEDs The red LED indicates that the device has power The green LED will blink when communicating with other devices Installation Guide Installing the MadgeTech 4 Software Insert the Data Logger Software Flash Drive into an open USB port on a Windows PC If the a...

Страница 12: ...wireless performance both the RFC1000 and the data loggers should be mounted in the same orientation This usually means that the external antenna should be pointing straight up The antenna can pivot to accommodate either a wall mount or a desk mount 10 ...

Страница 13: ...ata logger or RFC1000 that is on the same network is required to use the same channel If all of the devices are not on the same channel the devices will not communicate with one another The images below show the orientations available of the switches for each channel Channel 26 all switches in the up position is not supported 11 Follow the instructions below to configure the channel settings of th...

Страница 14: ... or there are walls obstacles corners that need to be maneuvered around set up additional RFC1000s as needed Step 3 Verify that the data loggers are in wireless transmission mode See Channel Programming steps above Step 4 On a Windows PC launch the MadgeTech 4 software program All active data loggers will be listed in the software showing that the device s are recognized Step 5 To activate the dat...

Страница 15: ...pplicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Under Industry Canada regulations this radio transmitter may only operate using an an...

Страница 16: ...software click the File button then click Options 2 In the Options window click Communications 3 The Detected Interfaces box will list all of the available communication interfaces If the RFC1000 is listed here then the software has correctly recognized and is ready to use it Check that Windows recognizes the connected RFC1000 wireless transceiver If the software does not recognize the RFC1000 the...

Отзывы: