CrossFire 8300/8301 Stacker Guide to Operation, DOC-7092 v. 1.0
4. Installation
Checking the Installation
Before you turn on the CrossFire stack equipment, inspect the equipment
thoroughly. Verify that all cables are installed correctly. Check cable routing to
make sure no cable will be damaged or create a safety hazard. Be sure all equipment
is mounted properly and securely.
Applying Power
➽
➽
➽
➽
Warning:
There are
no
ON/OFF switches on the CrossFire 8300 Switch Stacker,
the CrossFire 8600 Series Switches or the CrossFire 8730 Switches.
Power is on
when the unit is plugged into a power source
.
➽
➽
➽
➽
Important:
All switches in a stack must use the same software version. If any
switch uses a different software version, a warning message will appear on the
switch console, and the switch will not join the stack.
There are no user serviceable parts inside the CrossFire 8300 Switch Stacker or the
switch. Any internal upgrades or service should be performed by qualified
personnel
only
.
➽
➽
➽
➽
Warning:
Do not touch the power supply when the power cord is connected. Line
voltages are present within the power supply when the power cord is connected.
Use the following steps to power on your equipment.
1. Make sure that you are using the correct power source.
2. Using the supplied power cables, plug the female end of the cable into the AC
receptacle on the CrossFire 8300 Switch Stacker or the switch.
•
On the CrossFire 8300 Switch Stacker, the AC connector for the primary unit
is at the right on the back panel. The AC connector for the secondary
(redundant) unit is at the left on the back panel (see Figure 7).
Figure 7. The AC Connector for the Primary Power Supply Unit at the Right on
the CrossFire 8300 Back Panel
P1
P3
P5
P7
P2
P4
P6
P8
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following two
conditions. (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired operation.
For selection of power cord
set please refer to the manual
"Guide to Operations
For selection of power cord
set please refer to the manual
"Guide to Operations
DO NOT CONNECT THE POWER CORD
UNLESS ALL OPENINGS ARE CLOSED
BY BLIND PANELS
CAUTION!
WARNING!
THE CHASSIS MAY HAVE TWO POWER
SUPPLY UNITS. TO REDUCE THE RISK OF
ELECTRIC SHOCK, DISCONNECT THE TWO
POWER CORDS BEFORE ANY SERVICING
HIGH VOLTAGES
TOP COVER MAY ONLY
BE REMOVED BY
AUTHORIZED PERSONNEL
LISTED
I. T. E.
3C04
C
U
R
L
U
R
L
Содержание CrossFire 8300
Страница 2: ......
Страница 3: ...CrossFire TM 8300 Switch Stacker CrossFire TM 8301 Redundant Stacker Unit Guide to Operation...
Страница 10: ...viii CrossFire 8300 8301 Stacker Guide to Operation DOC 7092 v 1 0...
Страница 22: ...12 CrossFire 8300 8301 Stacker Guide to Operation DOC 7092 v 1 0 2 Switch Stacker Operation...
Страница 50: ...40 CrossFire 8300 8301 Stacker Guide to Operation DOC 7092 v 1 0 5 Accessing Switch Management...
Страница 60: ...50 CrossFire 8300 8301 Stacker Guide to Operation DOC 7092 v 1 0 6 Switch Configuration...
Страница 62: ...52 CrossFire 8300 8301 Stacker Guide to Operation DOC 7092 v 1 0 7 Madge Technical Support...
Страница 67: ......