7
1.7.1 Main view
– The volume measured is displayed for 12
seconds;
– The flow rate is displayed for 3 seconds;
– The display cycle is automatically repeat-
ed 4 times, for a total of 60 seconds (12+3
=15 x 4 =60).
1.7.2 Periodic readings
Following an automatic sequence, billing
date references are displayed:
– Date of reading 1 displayed for 3 seconds;
– Periodic reading 1 displayed for 3 sec-
onds;
– Date of reading 2 displayed for 3 seconds;
– Periodic reading 2 displayed for 3 sec-
onds.
The calendar icon is active during the dis-
play.
1.7.3 Display test and firmware version
The display is presented as follows:
– all segments active for 3 seconds;
– all segments off for 3 seconds;
– the installed firmware version is dis-
played for 3 seconds. The displayed for-
mat is
MM.mmF, in which MM indicates
the number (2 digits) of the main version,
mm indicates the number (2 digits) of the
secondary version and
F represents the
firmware;
– the firmware CRC for 3 seconds. The for-
mat displayed, using all 8 digits of the
display, is 32-bit hexadecimal using both
digits and letters (0-9/A-F);
– any error codes for 3 seconds (e.g. Err
XXXX, where XXXX is the hexadecimal code
1.7.4 Seals
The meter has a hole (1) at the side of the
body, which is designed for inserting a wire
seal when installing on site.
1