Installation Overview
AVD 370/2 FAN
© 2019 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
AVD 370/2 INSTALLATION MANUAL 90-30071-00 Rev A-01 Date: 030121
17
Glulam
1.
The Safety Cable needs to be fed through a hole in the Glulam, preferably above the center
line of the Glulam.
2.
The Control Panel must be secured to the Glulam with Glulam brackets and hardware kit.
3.
The Glulam brackets need to be through bolted to the Glulam as high as possible.
4.
Mount Fan Motor Unit using Rapid Commercial Mount or Universal Mount (UMH, not
shown) and drop extension onto the base of the control panel using hardware kit,
combination wrench, and/or Allen wrench.