11
Technical specifications (cont‘d)
Drives with integrated overload cutoff
SA 1500-xxx
Version
B1
Rated voltage (V)
24 (+30%/-20%)
Ripple allowed
5%
Nominal current consumption (A)
1,0
Cut-off current (A)
2,5
Starting current, short-time (A)
3,0
Nominal force (N)
1500
Locking force (N)
1950
Stroke/opening width xxx (mm)
300, 500, 700, 1000
Protection class
IP 65
Running period (mm/min)
110
Duty cycle
30% ED
Ambient temperature
-25 °C to +75 °C
Cutoff
integrated overload cutoff
Connection technology
incl. lead wire 2 x 1 mm²
stroke 300 = 1900 mm
stroke 500 = 2150 mm
stroke 750 = 2400 mm
stroke 1000 = 2600 mm
Dimensions (Ø x L in mm)
46 x 410
Housing
aluminium
Lifespan (Open/Closed cycles)
11.000
Accessories brackets (optional)
console KB6, sash bracket Ø8
Controls required
no
Synchron drives with external overload cutoff /
synchronous-run load cutoff
SA 650-xxx SYN SA 1000-xxx SYN
SA 650-xxx A SYN SA 1000-xxx A SYN
Version
A1 A1 A2 A2
Rated voltage (V)
24 (+4/-2)
24 (+4/-2)
24 (+4/-2)
24 (+4/-2)
Ripple allowed
5%
5%
5%
5%
Nominal current consumption (A)
0,8 / 1,1 (bei Hub 1000)
0,8 / 1,1 (bei Hub 1000)
Cut-off current (A)
2,0 / 2,3 (bei Hub 1000)
2,0 / 2,3 (bei Hub 1000)
Starting current, short-time (A)
2,0
2,0
2,0
2,0
Nominal force (N)
650
1000
650
1000
Locking force (N)
850
1300
850
1300
Stroke/opening width xxx (mm)
300, 500, 750, 1000
300, 500, 750, 1000
Protection class
IP 65
IP 65
IP 65
IP 65
Running period (mm/min)
375
200
375
200
Duty cycle
30% ED
30% ED
30% ED
30% ED
Ambient temperature
-20 °C to +70 °C
-20 °C to +70 °C
Cutoff
external overload cutoff integrated
external overload cutoff integrated
in synchronous-run load cutoff
in synchronous-run load cutoff
Connection technology
incl. lead wire 2 x 1 mm²,
incl. lead wire 2x1 mm²,
1 x 0,34 mm²
1 x 0,34 mm²
stroke 300 = 1700 mm
stroke 300 = 1700 mm
stroke 500 = 1900 mm
stroke 500 = 1900 mm
stroke 750 = 2150 mm
stroke 750 = 2150 mm
stroke 1000 = 2400 mm
stroke 1000 = 2400 mm
Dimensions (Ø x L in mm)
35 x 322
35 x 359
Housing
aluminium
aluminium
aluminium
aluminium
Lifespan (Open/Closed cycles)
11.000
11.000
11.000
11.000
Accessories brackets (optional)
console KB5, console WK1 Ø6, hinge bracket Ø6, sash console Ø32, sash bracket Ø6
Controls required
LA-SYN 0,55-2,5 A (synchronous-run load cutoff with 0,55 to 2,5 A)