background image

11

Technical specifications (cont‘d)

Drives with integrated overload cutoff   

 

 

SA 1500-xxx

Version 

   B1

Rated voltage (V)  

 

 

24 (+30%/-20%)

Ripple allowed 

 

   

5%

Nominal current consumption (A)  

 

 

1,0

Cut-off current (A) 

 

   

2,5

Starting current, short-time (A) 

 

   

3,0

Nominal force (N)  

 

 

1500

Locking force (N) 

 

 

1950

Stroke/opening width xxx (mm)  

 

 

300, 500, 700, 1000

Protection class  

 

 

IP 65

Running period (mm/min)  

 

 

110

Duty cycle 

 

 

30% ED

Ambient temperature  

 

 

-25 °C to +75 °C

Cutoff  

 

 

integrated overload cutoff

Connection technology  

 

 

incl. lead wire 2 x 1 mm²

 

 

 

stroke   300 = 1900 mm

 

 

 

stroke   500 = 2150 mm

 

 

 

stroke   750 = 2400 mm

 

   stroke  1000 = 2600 mm

Dimensions (Ø x L in mm) 

 

   

46 x 410

Housing  

 

 

aluminium

Lifespan (Open/Closed cycles)  

 

 

11.000

Accessories brackets (optional) 

 

 

console KB6, sash bracket Ø8

Controls required 

 

 

no

Synchron drives with external overload cutoff / 

synchronous-run load cutoff

  

SA 650-xxx SYN   SA 1000-xxx SYN  

SA 650-xxx A SYN   SA 1000-xxx A SYN

Version 

A1 A1  A2  A2

Rated voltage (V)  

24 (+4/-2) 

24 (+4/-2) 

24 (+4/-2) 

24 (+4/-2)

Ripple allowed 

5% 

  5% 

5% 

 

5%

Nominal current consumption (A)  

0,8 / 1,1 (bei Hub 1000)  

0,8 / 1,1 (bei Hub 1000)

Cut-off current (A) 

2,0 / 2,3 (bei Hub 1000) 

2,0 / 2,3 (bei Hub 1000)

Starting current, short-time (A) 

2,0 

  2,0 

2,0 

 

2,0

Nominal force (N)  

650  

1000  

650  

1000

Locking force (N) 

850 

1300 

850 

1300   

Stroke/opening width xxx (mm)  

 

300, 500, 750, 1000  

 

300, 500, 750, 1000

Protection class  

IP 65  

IP 65  

IP 65  

IP 65

Running period (mm/min)  

375  

200  

375  

200

Duty cycle 

30% ED 

30% ED 

30% ED 

30% ED

Ambient temperature  

 

-20 °C to +70 °C  

 

-20 °C to +70 °C

Cutoff  

  external overload cutoff integrated  

 external overload cutoff integrated 

 

  in synchronous-run load cutoff 

  in synchronous-run load cutoff

Connection technology  

incl. lead wire 2 x 1 mm²,  

incl. lead wire 2x1 mm², 

 

1 x 0,34 mm²  

 

1 x 0,34 mm²

 

stroke   300 = 1700 mm  

stroke   300 = 1700 mm

 

stroke   500 = 1900 mm  

stroke   500 = 1900 mm

 

stroke   750 = 2150 mm  

stroke   750 = 2150 mm

 stroke  1000 = 2400 mm  

stroke  1000 = 2400 mm

Dimensions (Ø x L in mm) 

 

35 x 322 

 

35 x 359

Housing  

aluminium  

aluminium  

aluminium  

aluminium

Lifespan (Open/Closed cycles)  

11.000  

11.000  

11.000  

11.000

Accessories brackets (optional) 

console KB5, console WK1 Ø6, hinge bracket Ø6, sash console Ø32, sash bracket Ø6

Controls required 

LA-SYN 0,55-2,5 A (synchronous-run load cutoff with 0,55 to 2,5 A)

Содержание HAUTAU SA 650N

Страница 1: ...age Important safety instructions 2 Scope of delivery 6 Functional description 6 Technical specifications 10 Detail drawings spindle drive 13 Detail drawings consoles sash brackets hinge brackets 14 A...

Страница 2: ...isungen The safety of personnel requires that the following instructions be observed Incorrect installation can lead to severe injury F r die Sicherheit von Personen ist es wichtig die folgenden Anwei...

Страница 3: ...en Sie immer ob Ihre Anlage den g ltigen Bestimmungen entspricht Notes Operation of the drive requires an additional control e g double pushbutton Use the drives only in combination with controls made...

Страница 4: ...ngsmittelhaltigen Mittel Sch tzen Sie den Antrieb dauerhaft vor Wasser Schmutz WARNING Important safety instructions cont d WARNUNG Wichtige Sicherheits anweisungen Forts Instructions These instructio...

Страница 5: ...g der Nutzung von Unterlagen nach ISO 16016 HAUTAU GmbH Installation Instructions The professional installation maintenance repair and disassembly of the drive must be entrusted to a person who is abl...

Страница 6: ...hrten Fall schlie t es wieder Funktionsbeschreibung The spindle drive is fastened above the frame bracket or sliding bracket on the window frame The control of the drive at the stile takes place at th...

Страница 7: ...minium Aluminium Lebensdauer Zyklen Auf Zu 11 000 11 000 11 000 11 000 Zubeh r Konsolen wahlweise Konsole KB5 Konsole WK1 6 Gelenkbock 6 Fl gelkonsole 32 Fl gelbock 6 ben tigte Steuerungen keine Antri...

Страница 8: ...5 5 Nennstromaufnahme A 0 8 1 1 bei Hub 1000 0 8 1 1 bei Hub 1000 Abschaltstrom A 2 0 2 3 bei Hub 1000 2 0 2 3 bei Hub 1000 Anlaufstrom kurzzeitig A 2 0 2 0 2 0 2 0 Nennkraft N 650 1000 650 1000 Zuha...

Страница 9: ...igte Steuerungen keine Synchronantriebe zur Verwendung mit externer Lastabschaltung Gleich lauflastabschaltung LA SYN SA 1000 xxx SYN SA 1500 xxx SYN SA 1800 xxx SYN SA 2000 xxx SYN SA 2500 xxx SYN Ba...

Страница 10: ...minium Lifespan Open Closed cycles 11 000 11 000 11 000 11 000 Accessories brackets optional console KB5 console WK1 6 hinge bracket 6 sash console 32 sash bracket 6 Controls required no Drives with e...

Страница 11: ...consumption A 0 8 1 1 bei Hub 1000 0 8 1 1 bei Hub 1000 Cut off current A 2 0 2 3 bei Hub 1000 2 0 2 3 bei Hub 1000 Starting current short time A 2 0 2 0 2 0 2 0 Nominal force N 650 1000 650 1000 Loc...

Страница 12: ...cles 11 000 11 000 11 000 11 000 11 000 Accessories brackets optional console KB6 sash bracket 8 Controls required LA SYN 1 0 7 0 A synchronous run load cutoff with 1 0 to 7 0 A Drives with integrated...

Страница 13: ...1 21 60 15 6 1 8 1 35 L Hub L stroke L Hub L stroke L 50 8 1 46 28 50 46 59 51 3 siehe Tabelle Technische Daten Abmessungen refer to table Technical specifications Dimensions siehe Tabelle Technische...

Страница 14: ...70 58 23 5 5 45 37 5 26 5 17 5 35 4 Nm max Anzugsmoment max tightening torque 68 62 M6x25 DIN 933 10 9 M6 DIN 985 10 6 5 40 65 80 43 58 70 32 40 15 5 Nm Anzugsmoment tightening torque Detailzeichnunge...

Страница 15: ...gel und Gelenkbock Forts Detail drawings consoles sash brackets hinge brackets cont d 6 5 137 120 100 90 78 22 10 10 22 40 5 41 5 6 5 137 120 100 85 50 15 10 27 23 50 5 41 5 6 6 2 11 1 32 1 21 1 20 1...

Страница 16: ...per part Unterteil Bottom part Detailzeichnungen Konsolen Fl gel und Gelenkbock Forts Detail drawings Brackets sash bracket hinge bracket cont d 12 8 1 0 6 33 20 8 23 6 5 35 50 16 33 22 10 28 6 5 52 1...

Страница 17: ...www hautau de Projektierungshilfe unter www hautau de Project planning tools at www hautau de Fenster Klappfl gel ausw rts Window top hung open out sash Montagem glichkeit f r die Konsole WK 1 6 und...

Страница 18: ...und Fl gelbock 6 Mounting option for sash console 32 and sash bracket 6 Anwendungsbeispiele Forts Application examples cont d Lichtkuppel Light dome Montagem glichkeiten f r die Konsole KB 5 und Fl g...

Страница 19: ...6 und Fl gelbock 8 Mounting options for console KB 6 and sash bracket 8 Anwendungsbeispiele Forts Application examples cont d Dachfl chenfenster Roof window Montagem glichkeit f r die Konsole KB 6 und...

Страница 20: ...vet nuts or reinforcement boards should be provided on site IMPORTANT The freedom of movement of the sash must be greater than the stroke of the drive The drive pivots around its fastening point durin...

Страница 21: ...oder Zentrale auszuf hren Die Polung der Antriebe ist zu beachten The wires of the drives may not be extended and have to be connected directly in a junction box or depending on the type of drive to t...

Страница 22: ...n case of overload and switches on again afterwards use mains power supply unit with higher current output drive does not switch off overload cutoff does not switch off due to low voltage use mains po...

Страница 23: ...spose of the device by transferring it to separate waste collection Do not dispose of the drive along with unsorted household waste Pflege Care F r die Reinigung der Geh useteile verwenden Sie ein wei...

Страница 24: ...HAUTAU GmbH Wilhelm Hautau Str 2 31691 Helpsen Germany Tel 49 5724 393 0 info hautau de www hautau de...

Отзывы: