background image

3

PRIMING

Start rotating the handle until fluid starts flowing from 
the outlet spout.

In the unusual event where the pump fails to prime.

Remove the outlet tube and pour about 30mL of the 
same type of liquid into the pump outlet, then re-fit the 
outlet spout and turn the handle to re-prime the pump.

TROUBLE

CAUSE

REMEDY

Pump does not          
dispense fluid.

1) Pump not able to 
    create adequate suction.

1) Prime pump. Refer to “Priming”. 

2) Pump is sucking in air.

2)   Tighten and /or re-seal all 

threaded connections.

Fluid leaking from 
handle seal.

1)  Damaged seal

(check fluid compatibility).

1)  Check fluid compatibility with the PTFE, 

replace damaged seal.

NOTE: No spare parts available

STAINLESS STEEL ROTARY DRUM PUMP 

TROUBLE SHOOTING GUIDE

oultet

Outlet

®

Instruction manual

 

lubematebymacnaught.com 

Содержание Lubemate L-SSRP

Страница 1: ...otary vane Wetted materials 304 SS PTFE and Viton Pump inlet outlet 3 4 BSPT F Flow rate Up to 4L 20 turns INTRODUCTION Thank you for purchasing a Lubemate Stainless Steel Rotary Drum Pump Your stainless steel rotary drum pump with PTFE vanes has been designed and manufactured to reliably dispense a wide range of fluids such as water based media anti freeze acids chemicals all petroleum based prod...

Страница 2: ...ng adaptor onto the drum Now tighten the bung adaptor securely to the suction tube GENERAL INFORMATION This self priming pump can pump fluid in reverse if required Please take a few moments to read this manual before installing and operating your stainless steel rotary pump Hydrochloric acid Sulfuric acid etc STAINLESS STEEL ROTARY DRUM PUMP 3 Assemble the suction tube using PTFE tape or other sui...

Страница 3: ...me the pump TROUBLE CAUSE REMEDY Pump does not dispense fluid 1 Pump not able to create adequate suction 1 Prime pump Refer to Priming 2 Pump is sucking in air 2 Tighten and or re seal all threaded connections Fluid leaking from handle seal 1 Damaged seal check fluid compatibility 1 Check fluid compatibility with the PTFE replace damaged seal NOTE No spare parts available STAINLESS STEEL ROTARY DR...

Страница 4: ...lly selected by our experienced technical team at Macnaught ensuring they meet our strict quality standards Macnaught Pty Ltd 41 49 Henderson St Turrella NSW 2205 Australia Ph 1800 185 102 Fax 61 2 9597 7773 Email info macnaught com au Website macnaught com To register your product warranty refer to www macnaught com warranty registration ...